Background: In recent years, there has been a rapid proliferation in micro-computed tomography (micro-CT) systems becoming more available for routine preclinical research, with applications in many areas including bone, lung, cancer and cardiac imaging. Micro-CT provides the means to noninvasively acquire detailed anatomical information, but high-resolution imaging comes at the cost of longer scan times and higher doses, which is not desirable given the potential risks related to x-ray radiation. To achieve dose reduction and higher throughputs without compromising image quality (noise management), fewer projections can be acquired. This is where iterative reconstruction methods can have the potential to reduce noise since these algorithms can better handle sparse projection data, compared to filtered backprojection Purpose: We evaluate the performance characteristics of a compact benchtop micro-CT scanner that provides iterative reconstruction capabilities with GPU-based acceleration. More specifically, we thereby investigate the potential benefit of iterative reconstruction methods for dose reduction.Methods: Based on a series of phantom experiments, the benchtop micro-CT system was characterized in terms of image uniformity, noise, low contrast detectability, linearity and spatial resolution. Whole-body images of a plasticized ex vivo mouse phantom were also acquired. Different acquisition protocols (general-purpose versus high-resolution, including low dose scans) and different This article is protected by copyright. All rights reserved. 3 reconstruction strategies (analytic versus iterative algorithms: FDK, ISRA, ISRA-TV) were compared.Results: Signal uniformity was maintained across the radial and axial field-of-view (no cupping effect) with an average difference in Hounsfield units (HU) between peripheral and central regions below 50. For low contrast detectability, regions with at least ∆HU of 40 to surrounding material could be discriminated (for rods of 2.5 mm diameter). A high linear correlation (R 2 = 0.997) was found between measured CT values and iodine concentrations (0-40 mg/ml). Modulation transfer function (MTF) calculations on a wire phantom evaluated a resolution of 10.2 lp/mm at 10% MTF that was consistent with the 8.3% MTF measured on the 50 µm bars (10 lp/mm) of a bar-pattern phantom. Noteworthy changes in signal-to-noise and contrast-to-noise values were found for different acquisition and reconstruction protocols. Our results further showed the potential of iterative reconstruction methods to deliver images with less noise and artefacts. Conclusions:In summary, the micro-CT system for laboratory animal imaging that was evaluated in the present work was shown to provide a good combination of performance characteristics between image uniformity, low contrast detectability and resolution in short scan times. With the iterative reconstruction capabilities of this micro-CT system in mind (ISRA and ISRA-TV), the adoption of such algorithms by GPU-based acceleration enables the integration of no...
Purpose Long axial field-of-view (LAFOV) systems have a much higher sensitivity than standard axial field-of-view (SAFOV) PET systems for imaging the torso or full body, which allows faster and/or lower dose imaging. Despite its very high sensitivity, current total-body PET (TB-PET) throughput is limited by patient handling (positioning on the bed) and often a shortage of available personnel. This factor, combined with high system costs, makes it hard to justify the implementation of these systems for many academic and nearly all routine nuclear medicine departments. We, therefore, propose a novel, cost-effective, dual flat panel TB-PET system for patients in upright standing positions to avoid the time-consuming positioning on a PET-CT table; the walk-through (WT) TB-PET. We describe a patient-centered, flat panel PET design that offers very efficient patient throughput and uses monolithic detectors (with BGO or LYSO) with depth-of-interaction (DOI) capabilities and high intrinsic spatial resolution. We compare system sensitivity, component costs, and patient throughput of the proposed WT-TB-PET to a SAFOV (= 26 cm) and a LAFOV (= 106 cm) LSO PET systems. Methods Patient width, height (= top head to start of thighs) and depth (= distance from the bed to front of patient) were derived from 40 randomly selected PET-CT scans to define the design dimensions of the WT-TB-PET. We compare this new PET system to the commercially available Siemens Biograph Vision 600 (SAFOV) and Siemens Quadra (LAFOV) PET-CT in terms of component costs, system sensitivity, and patient throughput. System cost comparison was based on estimating the cost of the two main components in the PET system (Silicon Photomultipliers (SiPMs) and scintillators). Sensitivity values were determined using Gate Monte Carlo simulations. Patient throughput times (including CT and scout scan, patient positioning on bed and transfer) were recorded for 1 day on a Siemens Vision 600 PET. These timing values were then used to estimate the expected patient throughput (assuming an equal patient radiotracer injected activity to patients and considering differences in system sensitivity and time-of-flight information) for WT-TB-PET, SAFOV and LAFOV PET. Results The WT-TB-PET is composed of two flat panels; each is 70 cm wide and 106 cm high, with a 50-cm gap between both panels. These design dimensions were justified by the patient sizes measured from the 40 random PET-CT scans. Each panel consists of 14 × 20 monolithic BGO detector blocks that are 50 × 50 × 16 mm in size and are coupled to a readout with 6 × 6 mm SiPMs arrays. For the WT-TB-PET, the detector surface is reduced by a factor of 1.9 and the scintillator volume by a factor of 2.2 compared to LAFOV PET systems, while demonstrating comparable sensitivity and much better uniform spatial resolution (< 2 mm in all directions over the FOV). The estimated component cost for the WT-TB-PET is 3.3 × lower than that of a 106 cm LAFOV system and only 20% higher than the PET component costs of a SAFOV. The estimated maximum number of patients scanned on a standard 8-h working day increases from 28 (for SAFOV) to 53–60 (for LAFOV in limited/full acceptance) to 87 (for the WT-TB-PET). By scanning faster (more patients), the amount of ordered activity per patient can be reduced drastically: the WT-TB-PET requires 66% less ordered activity per patient than a SAFOV. Conclusions We propose a monolithic BGO or LYSO-based WT-TB-PET system with DOI measurements that departs from the classical patient positioning on a table and allows patients to stand upright between two flat panels. The WT-TB-PET system provides a solution to achieve a much lower cost TB-PET approaching the cost of a SAFOV system. High patient throughput is increased by fast patient positioning between two vertical flat panel detectors of high sensitivity. High spatial resolution (< 2 mm) uniform over the FOV is obtained by using DOI-capable monolithic scintillators.
Investigate the use of deep learning (DL) approaches for denoising low dose micro-CT images. 2. Compare the performance with other methods to show and quantify the impact of DL-based image enhancement on micro-CT datasets.
Purpose: Positron Emission Tomography (PET) image quality can be improved by higher injected activity and/or longer acquisition time, but both may often not be practical in preclinical imaging. Common preclinical radioactive doses (10 MBq) have been shown to cause deterministic changes in biological pathways. Reducing the injected tracer activity and/or shortening the scan time inevitably results in low-count acquisitions which poses a challenge because of the inherent noise introduction. We present an image-based deep learning (DL) framework for denoising lower count micro-PET images. Procedures: For 36 mice, a 15-min 18F-FDG (8.15 ± 1.34 MBq) PET scan was acquired at 40 min post-injection on the Molecubes b-CUBE (in list mode). The 15-min acquisition (high-count) was parsed into smaller time fractions of 7.50, 3.75, 1.50 and 0.75 mins to emulate images reconstructed at 50, 25, 10 and 5% of the full counts, respectively. A 2D U-Net was trained with mean-squared-error loss on 28 high-low count image pairs. Results: The DL algorithms were visually and quantitatively compared to spatial and edge-preserving denoising filters; the DL-based methods effectively removed image noise and recovered image details much better while keeping quantitative (SUV) accuracy. The largest improvement in image quality was seen in the images reconstructed with 10 and 5% of the counts (equivalent to sub-1-MBq or sub-1-min mouse imaging). The DL-based denoising framework was also successfully applied on the NEMA-NU4 phantom and different tracer studies (18F-PSMA, 18F-FAPI and 68Ga-FAPI). Conclusion: Visual and quantitative results support the superior performance and robustness in image denoising of the implemented DL models for low statistics micro-PET. This offers tremendous flexibility in optimizing scan protocols with reduced tracer doses or shorter durations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.