This paper presents two infrared thermography methods with CO 2 Laser excitation and microwave excitation applied to defect detection in CFRP. The tests were conducted with two specimens, one with defect, and another one without defect. On two concrete plates 40 cm × 40 cm × 4.5 cm were reinforced by CFRP; the defects were made by the absence of adhesive on an area 10 cm × 10 cm. The specimens were heated by microwave, generated by a commercial magnetron of 2.45 GHz and guided by a pyramidal horn antenna, with a power of 360 W within 150 s. Another series of the tests was conducted with CO 2 Laser, wavelength 10.6 µm, by heating the samples with a power of 300 W within 40 s. An infrared camera sensitive to medium waves in range of 3-5 μm, with a detector of 320 × 256 matrix detector in InSb (Indium Antimonide), was used to record the thermograms. As a result, the CO 2 Laser excitation is better for the delamination detection in CFRP. This study opens interesting perspectives for inspecting other types of defects in materials sciences; the microwave excitation is suitable for the deep defects in the materials whereas the CO 2 Laser excitation is better for the defects near the surface of the materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.