Object reconstruction from a series of projection images, such as in computed tomography (CT), is a popular tool in many different application fields. Existing commercial software typically provides sufficiently accurate and convenient-to-use reconstruction tools to the end-user. However, in applications where a non-standard acquisition protocol is used, or where advanced reconstruction methods are required, the standard software tools often are incapable of computing accurate reconstruction images. This article introduces the ASTRA Toolbox. Aimed at researchers across multiple tomographic application fields, the ASTRA Toolbox provides a highly efficient and highly flexible open source set of tools for tomographic projection and reconstruction. The main features of the ASTRA Toolbox are discussed and several use cases are presented.
A new reconstruction approach for electron tomography is proposed, enabling a detailed 3D analysis of assemblies with as many as 10 000 particles.
a b s t r a c tIn electron tomography, the fidelity of the 3D reconstruction strongly depends on the employed reconstruction algorithm. In this paper, the properties of SIRT, TVM and DART reconstructions are studied with respect to having only a limited number of electrons available for imaging and applying different angular sampling schemes. A well-defined realistic model is generated, which consists of tubular domains within a matrix having slab-geometry. Subsequently, the electron tomography workflow is simulated from calculated tilt-series over experimental effects to reconstruction. In comparison with the model, the fidelity of each reconstruction method is evaluated qualitatively and quantitatively based on global and local edge profiles and resolvable distance between particles. Results show that the performance of all reconstruction methods declines with the total electron dose. Overall, SIRT algorithm is the most stable method and insensitive to changes in angular sampling. TVM algorithm yields significantly sharper edges in the reconstruction, but the edge positions are strongly influenced by the tilt scheme and the tubular objects become thinned. The DART algorithm markedly suppresses the elongation artifacts along the beam direction and moreover segments the reconstruction which can be considered a significant advantage for quantification. Finally, no advantage of TVM and DART to deal better with fewer projections was observed.
Regularized iterative reconstruction methods in computed tomography can be effective when reconstructing from mildly inaccurate undersampled measurements. These approaches will fail, however, when more prominent data errors, or outliers, are present. These outliers are associated with various inaccuracies of the acquisition process: defective pixels or miscalibrated camera sensors, scattering, missing angles, etc. To account for such large outliers, robust data misfit functions, such as the generalized Huber function, have been applied successfully in the past. In conjunction with regularization techniques, these methods can overcome problems with both limited data and outliers. This paper proposes a novel reconstruction approach using a robust data fitting term which is based on the Student’s t distribution. This misfit promises to be even more robust than the Huber misfit as it assigns a smaller penalty to large outliers. We include the total variation regularization term and automatic estimation of a scaling parameter that appears in the Student’s t function. We demonstrate the effectiveness of the technique by using a realistic synthetic phantom and also apply it to a real neutron dataset
Abstract. As tomographic imaging is being performed at increasingly smaller scales, the stability of the scanning hardware is of great importance to the quality of the reconstructed image. Instabilities lead to perturbations in the geometrical parameters used in the acquisition of the projections. In particular for electron tomography and high-resolution X-ray tomography, small instabilities in the imaging setup can lead to severe artifacts. We present a novel alignment algorithm for recovering the true geometrical parameters after the object has been scanned, based on measured data. Our algorithm employs an optimization algorithm that combines alignment with reconstruction. We demonstrate that problemspecific design choices made in the implementation are vital to the success of the method. The algorithm is tested in a set of simulation experiments. Our experimental results indicate that the method is capable of aligning tomography datasets with considerably higher accuracy compared to standard cross-correlation methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.