Purpose: This study investigated the position of the hyoid bone and its relationship with airway dimensions in different skeletal malocclusion classes using cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans of 180 participants were categorized based on the A point-nasion-B point angle into class I, class II, and class III malocclusions. Eight linear and 2 angular hyoid parameters (H-C3, H-EB, H-PNS, H-Me, H-X, H-Y, H-[C3-Me], C3-Me, H-S-Ba, and H-N-S) were measured. A 3-dimensional airway model was designed to measure the minimum cross-sectional area, volume, and total and upper airway length. The mean crosssectional area, morphology, and location of the airway were also evaluated. Data were analyzed using analysis of variance and the Pearson correlation test, with P values <0.05 indicating statistical significance. Results: The mean airway volume differed significantly among the malocclusion classes (P<0.05). The smallest and largest volumes were noted in class II (2107.8±844.7 mm 3 ) and class III (2826.6±2505.3 mm 3 ), respectively. The means of most hyoid parameters (C3-Me, C3-H, H-Eb, H-Me, H-S-Ba, H-N-S, and H-PNS) differed significantly among the malocclusion classes. In all classes, H-Eb was correlated with the minimum cross-sectional area and airway morphology, and H-PNS was correlated with total airway length. A significant correlation was also noted between H-Y and total airway length in class II and III malocclusions and between H-Y and upper airway length in class I malocclusions. Conclusion:The position of the hyoid bone was associated with airway dimensions and should be considered during orthognathic surgery due to the risk of airway obstruction.
Purpose This study investigated the accuracy of laser-scanned models and 3-dimensional (3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. Materials and Methods CBCT scans and plaster models from 30 patients were retrieved. Plaster models were scanned by an Emerald laser scanner (Planmeca, Helsinki, Finland). Sixteen different measurements, encompassing the mesiodistal width of teeth and both arches’ length and width, were calculated using various landmarks. Linear measurements were made on laser-scanned models using Autodesk Meshmixer software v. 3.0 (Autodesk, Mill Valley, CA, USA), on 3D-rendered CBCT models using OnDemand 3D v. 1.0 (Cybermed, Seoul, Korea) and on plaster casts by a digital caliper. Descriptive statistics, the paired t-test, and intra- and inter-class correlation coefficients were used to analyze the data. Results There were statistically significant differences between some measurements on plaster casts and laser-scanned or 3D-rendered CBCT models ( P <0.05). Molar mesiodistal width and mandibular anterior arch width deviated significantly different from the gold standard in both methods. The largest mean differences of laser-scanned and 3D-rendered CBCT models compared to the gold standard were 0.12±0.23 mm and 0.42±0.53 mm, respectively. Most of the mean differences were not clinically significant. The intra- and inter-class correlation results were acceptable for all measurements (>0.830) and between observers (>0.801). Conclusion The 3D-rendered CBCT images and laser-scanned models were useful and accurate alternatives to conventional plaster models. They could be used for clinical purposes in orthodontics and prostheses.
This study evaluated the effect of different amperage values and voxel sizes of two CBCT scanners on VRF detection in the presence of different intracanal posts. After post‐space preparation, VRFs were induced in half of the samples of 20 maxillary premolars. Five different intracanal posts were passively placed in each root canal. Samples were scanned using CS 9300 and Cranex3D with two different voxel sizes and amperage setting in each unit. The diagnostic sensitivity, specificity and accuracy were compared using the Mann–Whitney and Kruskal‐Wallis tests (α = 0.05). Changes in amperage and voxel size did not affect the detection of VRFs (p ⟩ 0.05). The VRF detection accuracy was the highest in fibreglass and the lowest in nickel‐chromium group. Changes in amperage and voxel size within assessed values do not seem to influence the detection of VRF whereas different intracanal post‐materials have significant effect on VRF detection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.