Single-jet meters are one of the most frequently used domestic meters that can be found in water distribution systems. Like any other water meter technology, they have significant metrological limitations that prevent them, even if recently installed, from measuring all water consumption of a domestic customer. After installation, their metrological characteristics evolve depending on the particular design of the meters and their actual working conditions in the field. This work presents a comprehensive set of tests to determine the initial and after installation weighted error of two types of domestic single-jet water meters. Three non-linear degradation models have been derived from the tests results. These models consider age, totalised volume, or both parameters simultaneously as drivers of the weighted error. The results show that even though the construction of the two examined meters is similar, they have been working under comparable operational conditions and measuring water of the same quality, there is a significant difference in the performance between both types. This result highlights the need to conduct individual analyses for each meter type and the impossibility of generalizing conclusions on how the weighted error could evolve over time.
Accurate water consumption measurement of customers is a crucial component of water utility sustainability. During the last decade, sophisticated measuring technologies without moving components, known as solid-state water meters or static meters, have emerged. Solid-state water meters promise an improved accuracy with more processing and transmission capabilities in comparison with traditional mechanical meters. A compromise needs to be reached between energy consumption and battery life as all these new features are extremely demanding on electric energy. The usual approach adopted by the manufacturer is to reduce the frequency with which static meters take measurements of the circulating flow. This reduction in signal sampling frequency can have a significant effect on the accuracy of the instruments when measuring water consumption events of 30 s or less, these events being common in residential customers. The research presented analyses of the metrological performance of 28 commercially available solid-state water meters from six different manufacturers in the presence of intermittent flows of various durations. The results show that the magnitude and dispersion of the error under intermittent flows is significantly larger in comparison to steady state flow conditions. The ultrasonic meters examined were more influenced by the intermittency than the electromagnetic meters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with đź’™ for researchers
Part of the Research Solutions Family.