Background: Volume overload is the main factor responsible for the pathogenesis of hypertension in dialysis patients. Few studies have evaluated the interpretation of the parameters obtained by bioelectrical impedance (BIA) to manage these patients. The aim of this study was to assess the best cutoff level of volume overload obtained by BIA able to predict the absence of hypertension control in hemodialysis patients. Methods: Volume overload was calculated as the difference between total body water (TBW) measured by bioimpedance and TBW estimated by the Watson formula in chronic stable hemodialysis patients. Inadequate control of blood pressure (BP) was defined as the mean of measurements obtained before five hemodialysis sessions ≥140 × 90 mm Hg. The best cutoff level of volume overload assessed by BIA able to predict the absence of BP control in patients on chronic hemodialysis was determined by the receiver operating characteristic (ROC) curve using the Youden method. Results: We included 205 patients, 53% male, aged 56 ± 14.5 years. The largest area under the ROC curve was found for predialysis volume overload (0.660, 95% CI 0.556-0.765, p = 0.004). The ROC curve of postdialysis volume overload also reaches statistical significance. The best cutoff point was found for predialysis volume overload ≥1.4 liters with a sensitivity of 69% and a specificity of 67%. Conclusion: The association of TBW and inadequate BP control highlights the importance of volume management in hemodialysis patients. Predialysis volume overload of 1.4 liters was the parameter that best discriminated the presence of inadequate BP control.
Background: Protein-energy wasting is related to impairment of quality of life and lower survival of end-stage kidney disease (ESKD) patients. The evaluation of body composition, especially fat free mass (FFM) and fat mass (FM), is important for the prediction of outcomes in these individuals. The aim of this study was to compare the FFM and FM measurements obtained by single-frequency bioimpedance (SF-BIA) and by a multiple frequency bioimpedance (MF-BIA) device, using dual energy X-ray absorptiometry (DXA) peritoneal dialysis (PD) patients.Methods: This was a cross-sectional study involving adult patients undergoing regular PD, in which we performed SF-BIA, MF-BIA, and DXA at the same visit. To compare the bioimpedance values with DXA, we used: Person correlation (r), intraclass correlation coefficient (ICC), and Bland-Altman concordance analysis.Results: The sample consisted of 50 patients in the PD, with mean age of 55.1 ± 16.3 years. Both bioimpedance methods showed a strong correlation (r > 0.7) and excellent reproducibility (ICC > 0.75) compared to DXA. According to the Bland-Altman diagram, SF-BIA showed agreement in body compartment measurements, with no proportionality bias (p > 0.05), without systematic bias for FFM (−0.5 ± 4.9, 95% CI −1.8 to 0.9, p = 0.506), and for FM (0.3 ± 4.6, p = 0.543). MF-BIA did not present a proportionality bias for the FFM, but it underestimated this body compartment by 2.5 ± 5.4 kg (p = 0.002). In addition, MF-BIA presented proportionality bias for FM.Conclusion: SF-BIA was a more accurate assessing method than MBIA for FFM and FM measurements in PD patients. Because it is a low-cost, non-evaluator-dependent measurement and has less systematic bias, it can also be recommended for fat mass and free-fat mass evaluation in PD patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.