Skeletal muscle contains intramyocellular lipid droplets within the cytoplasm of myocytes as well as intermuscular adipocytes. These depots exhibit physiological and pathological variation which has been revealed with the advent of diagnostic imaging approaches: magnetic resonance (MR) imaging, MR spectroscopy and computed tomography (CT). CT uses computer-processed X-rays and is now being applied in muscle physiology research. The purpose of this review is to present CT methodologies and summarize factors that influence muscle radiation attenuation, a parameter which is inversely related to muscle fat content. Pre-defined radiation attenuation ranges are used to demarcate intermuscular adipose tissue [from −190 to −30 Hounsfield units (HU)] and muscle (−29 HU to +150 HU). Within the latter range, the mean muscle radiation attenuation [muscle (radio) density] is reported. Inconsistent criteria for the upper and lower HU cut-offs used to characterize muscle attenuation limit comparisons between investigations. This area of research would benefit from standardized criteria for reporting muscle attenuation. Available evidence suggests that muscle attenuation is plastic with physiological variation induced by the process of ageing, as well as by aerobic training, which probably reflects accumulation of lipids to fuel aerobic work. Pathological variation in muscle attenuation reflects excess fat deposition in the tissue and is observed in people with obesity, diabetes type II, myositis, osteoarthritis, spinal stenosis and cancer. A poor prognosis and different types of morbidity are predicted by the presence of reduced mean muscle attenuation values in patients with these conditions; however, the biological features of muscle with these characteristics require further investigation.
By standardizing the renal absorbed dose delivered during the induction course, P-PRRT has the potential to significantly increase tumour absorbed dose, thus to augment the therapeutic benefit while limiting toxicity.
BackgroundRoutine dosimetry is essential for personalized 177Lu-octreotate peptide receptor radionuclide therapy (PRRT) of neuroendocrine tumors (NETs), but practical and robust dosimetry methods are needed for wide clinical adoption. The aim of this study was to assess the accuracy and inter-observer reproducibility of simplified dosimetry protocols based on quantitative single-photon emission computed tomography (QSPECT) with a limited number of scanning time points. We also updated our personalized injected activity (IA) prescription scheme.MethodsSeventy-nine NET patients receiving 177Lu-octreotate therapy (with a total of 279 therapy cycles) were included in our study. Three-time-point (3TP; days 0, 1, and 3) QSPECT scanning was performed following each therapy administration. Dosimetry was obtained using small volumes of interest activity concentration sampling for the kidney, the bone marrow and the tumor having the most intense uptake. Accuracy of the simplified dosimetry based on two-time-point (2TP; days 1 and 3, monoexponential fit) or a single-time-point (1TPD3; day 3) scanning was assessed, as well as that of hybrid methods based on 2TP for the first cycle and 1TP (day 1 or 3; 2TP/1TPD1 and 2TP/1TPD3, respectively) or no imaging at all (based on IA only; 2TP/no imaging (NI)) for the subsequent induction cycles. The inter-observer agreement was evaluated for the 3TP, 2TP, and hybrid 2TP/1TPD3 methods using a subset of 60 induction cycles (15 patients). The estimated glomerular filtration rate (eGFR), body size descriptors (weight, body surface area (BSA), lean body weight (LBW)), and products of both were assessed for their ability to predict IA per renal absorbed dose at the first cycle.ResultsThe 2TP dosimetry estimates correlated highly with those from the 3TP data for all tissues (Spearman r > 0.99, P < 0.0001) with small relative errors between the methods, particularly for the kidney and the tumor, with median relative errors not exceeding 2% and interdecile ranges spanning over less than 6% and 4%, respectively, for the per-cycle and cumulative estimates. For the bone marrow, the errors were slightly greater (median errors < 6%, interdecile ranges < 14%). Overall, the strength of correlations of the absorbed dose estimates from the simplified methods with those from the 3TP scans tended to progressively decrease, and the relative errors to increase, in the following order: 2TP, 2TP/1TPD3, 1TPD3, 2TP/1TPD1, and 2TP/NI. For the tumor, the 2TP/NI scenario was highly inaccurate due to the interference of the therapeutic response. There was an excellent inter-observer agreement between the three observers, in particular for the renal absorbed dose estimated using the 3TP and 2TP methods, with mean errors lesser than 1% and standard deviations of 5% or lower. The eGFR · LBW and eGFR · BSA products best predicted the ratio of IA to the renal dose (GBq/Gy) for the first cycle (Spearman r = 0.41 and 0.39, respectively; P < 0.001). For the first cycle, the personalized IA proportional to eGFR · LBW or eG...
Recent studies have supported a role for amyloid positron emission tomography (PET) imaging in distinguishing Alzheimer's disease (AD) pathology from other pathological protein accumulations leading to dementia. We investigated the clinical utility of amyloid PET in the differential diagnosis of atypical dementia cases and its impact on caregivers. Using the amyloid tracer 18F-NAV4694, we prospectively scanned 28 patients (mean age 59.3 y, s.d. 5.8; mean MMSE 21.4, s.d. 6.0) with an atypical dementia syndrome. Following a comprehensive diagnostic workup (i.e., history taking, neurological examination, blood tests, neuropsychological evaluation, MRI, and FDG-PET), no certain diagnosis could be arrived at. Amyloid PET was then conducted and classified as positive or negative. Attending physicians were asked to evaluate whether this result led to a change in diagnosis or altered management. They also reported their degree of confidence in the diagnosis. Caregivers were met after disclosure of amyloid PET results and completed a questionnaire/interview to assess the impact of the scan. Our cohort was evenly divided between positive (14/28) and negative (14/28) 18F-NAV4694 cases. Amyloid PET resulted in a diagnostic change in 9/28 cases (32.1%: 17.8% changed from AD to non-AD, 14.3% from non-AD to AD). There was a 44% increase in diagnostic confidence. Altered management occurred in 71.4% (20/28) of cases. Knowledge of amyloid status improved caregivers' outcomes in all domains (anxiety, depression, disease perception, future anticipation, and quality of life). This study suggests a useful additive role for amyloid PET in atypical cases with an unclear diagnosis beyond the extensive workup of a tertiary memory clinic. Amyloid PET increased diagnostic confidence and led to clinically significant alterations in management. The information gained from that test was well received by caregivers and encouraged spending quality time with their loved ones.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.