The tumor microenvironment is composed of cellular and stromal components such as tumor cells, mesenchymal cells, immune cells, cancer associated fibroblasts and the supporting extracellular matrix. The tumor microenvironment provides crucial support for growth and progression of tumor cells and affects tumor response to therapeutic interventions. To better understand tumor biology and to develop effective cancer therapeutic agents it is important to develop preclinical platforms that can faithfully recapitulate the tumor microenvironment and the complex interaction between the tumor and its surrounding stromal elements. Drug studies performed in vitro with conventional two-dimensional cancer cell line models do not optimally represent clinical drug response as they lack true tumor heterogeneity and are often performed in static culture conditions lacking stromal tumor components that significantly influence the metabolic activity and proliferation of cells. Recent microfluidic approaches aim to overcome such obstacles with the use of cell lines derived in artificial three-dimensional supportive gels or micro-chambers. However, absence of a true tumor microenvironment and full interstitial flow, leads to less than optimal evaluation of tumor response to drug treatment. Here we report a continuous perfusion microfluidic device coupled with microscopy and image analysis for the assessment of drug effects on intact fresh tumor tissue. We have demonstrated that fine needle aspirate biopsies obtained from patient-derived xenograft models of adenocarcinoma of the lung can successfully be analyzed for their response to ex vivo drug treatment within this biopsy trapping microfluidic device, wherein a protein kinase C inhibitor, staurosporine, was used to assess tumor cell death as a proof of principle. This approach has the potential to study tumor tissue within its intact microenvironment to better understand tumor response to drug treatments and eventually to choose the most effective drug and drug combination for individual patients in a cost effective and timely manner.
While many advanced liver models support hepatic phenotypes necessary for drug and disease studies, these models are characterized by intricate features such as co-culture with one of more supporting cell types or advanced media perfusion systems. These systems have helped elucidate some of the critical biophysical features missing from standard well-plate based hepatocyte culture, but their advanced designs add to their complexity. Additionally, regardless of the culture system, primary hepatocyte culture systems suffer from reproducibility issues due to phenotypic variation and expensive, limited supplies of donor lots. Here we describe a microfluidic bilayer device that sustains primary human hepatocyte phenotypes, including albumin production, factor IX production, cytochrome P450 3A4 drug metabolism and bile canaliculi formation for at least 14 days in a simple monoculture format with static media. Using a variety of channel architectures, we describe how primary cell phenotype is promoted by spatial confinement within the microfluidic channel, without the need for perfusion or co-culture. By sourcing human hepatocytes expanded in the Fah, Rag2, and Il2rg-knockout (FRG™-KO) humanized mouse model, utilizing a few hundred hepatocytes within each channel, and maintaining hepatocyte function for weeks in vitro within a relatively simple model, we demonstrate a basic primary human hepatocyte culture system that addresses many of the major hurdles in human hepatocyte culture research.Electronic supplementary materialThe online version of this article (doi:10.1007/s10544-014-9877-x) contains supplementary material, which is available to authorized users.
Analysis and separation of atomic ions within a portable setting are studied in forensic applications of radiological debris analysis. Ion mobility spectrometry (IMS) may be used to show separation of atomic ions, while the related method of differential mobility spectrometry (DMS) has focused on fractionation of primarily molecular components. We set out to investigate DMS as a means for separating atomic ions. We initially derived the differential ion mobility parameter, alpha, from classic empirical IMS data of atomic ions, cesium and potassium, each showing its own distinct form of alpha. These alpha functions were applied to DMS simulations and supported by analytical treatment that suggested a means for a rapid disambiguation of atomic ions using DMS. We validated this hypothesis through the prototype cesium-potassium system investigated experimentally by DMS coupled to mass spectrometry (MS). Such a feature would be advantageous in a field portable instrument for rapid atomic analyses especially in the case of isobaric ions that cannot be distinguished by MS. Herein, we first report this novel method for the derivation of alpha from existing field dependent drift tube ion mobility data. Further, we translate experimental DMS data into alpha parameters by expanding upon existing methods. Refining the alpha parameter in this manner helps convey the interpretation of the alpha parameter particularly for those new to the DMS field.
Differential mobility spectrometry (DMS) is applied to the analysis of inorganic mixtures relevant to nuclear forensics. Three primary components of potential radiological dispersal devices (RDDs), cobalt, cesium, and strontium, were studied by DMS to demonstrate rapid sample cleanup when coupled to mass spectrometry. Nanosprayed salt solutions comprised of stable analogs, as proxies to these radioisotopes, and isobaric interferents were introduced to DMS. The DMS effluent was directly coupled to a mass spectrometer to confirm the elemental identity of the separated clusters. DMS dispersion plots demonstrated distinctive elemental separation from both atomic and molecular interferents. These results support the potential use of DMS as a means of rapid separation for inorganic analyses prior to analysis in a field portable mass spectrometer. The mechanism for this process is speculated to involve dynamics of solvent cluster formation under the influence of the alternating high and low electric fields of the DMS.
Microfluidic systems enable reactions and assays on the scale of nanoliters. However, at this scale nonuniformities in sample delivery become significant. To determine the fundamental minimum sample volume required for a particular device, a detailed understanding of mass transport is required. Co-flowing laminar streams are widely used in many devices, but typically only in the steady-state. Because establishing the co-flow steady-state consumes excess sample volume and time, there is a benefit to operating devices in the transient state, which predominates as the volume of the co-flow reactor decreases. Analysis of the co-flow transient has been neglected thus far. In this work we describe the fabrication of a pneumatically controlled microfluidic injector constructed to inject a discrete 50nL bolus into one side of a two-stream co-flow reactor. Using dye for image analysis, injections were performed at a range of flow rates from 0.5-10μL/min, and for comparison we collected the co-flow steady-state data for this range. The results of the image analysis were also compared against theory and simulations for device validation. For evaluation, we established a metric that indicates how well the mass distribution in the bolus injection approximates steady-state co-flow. Using such analysis, transient-state injections can approximate steady-state conditions within predefined errors, allowing straight forward measurements to be performed with reduced reagent consumption.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.