Background: An advanced version of a recently reported high-throughput fermentation system with online measurement, called BioLector, and its validation is presented. The technology combines high-throughput screening and high-information content by applying online monitoring of scattered light and fluorescence intensities in continuously shaken microtiter plates. Various examples in calibration of the optical measurements, clone and media screening and promoter characterization are given.
Most experiments in screening and process development are performed in shaken bioreactors. Today, microtiter plates are the preferred vessels for small-scale microbial cultivations in high throughput, even though they have never been optimized for this purpose. To interpret the experimental results correctly and to obtain a base for a meaningful scale-up, sufficient oxygen supply to the culture liquid is crucial. For shaken bioreactors this problem can generally be addressed by the introduction of baffles. Therefore, the focus of this study is to investigate how baffling and the well geometry affect the maximum oxygen transfer capacity (OTR(max)) in microtiter plates. On a 48-well plate scale, 30 different cross-section geometries of a well were studied. It could be shown that the introduction of baffles into the common circular cylinder of a microtiter plate well doubles the maximum oxygen transfer capacity, resulting in values above 100 mmol/L/h (k(L)a > 600 1/h). To also guarantee a high volume for microbial cultivation, it is important to maximize the filling volume, applicable during orbital shaking. Additionally, the liquid height at the well bottom was examined, which is a decisive parameter for online-monitoring systems such as the BioLector. This technology performs fiber-optical measurements through the well bottom, therefore requires a constant liquid height at all shaking frequencies. Ultimately, a six-petal flower-shaped well geometry was shown to be the optimal solution taking into account all aforementioned criteria. With its favorable culture conditions and the possibility for unrestricted online monitoring, this novel microtiter plate is an efficient tool to gain meaningful results for interpreting and scaling-up experiments in clone screening and bioprocess development.
Background: In industry and academic research, there is an increasing demand for flexible automated microfermentation platforms with advanced sensing technology. However, up to now, conventional platforms cannot generate continuous data in high-throughput cultivations, in particular for monitoring biomass and fluorescent proteins. Furthermore, microfermentation platforms are needed that can easily combine cost-effective, disposable microbioreactors with downstream processing and analytical assays.
In industrial-scale biotechnological processes, the active control of the pH-value combined with the controlled feeding of substrate solutions (fed-batch) is the standard strategy to cultivate both prokaryotic and eukaryotic cells. On the contrary, for small-scale cultivations, much simpler batch experiments with no process control are performed. This lack of process control often hinders researchers to scale-up and scale-down fermentation experiments, because the microbial metabolism and thereby the growth and production kinetics drastically changes depending on the cultivation strategy applied. While small-scale batches are typically performed highly parallel and in high throughput, large-scale cultivations demand sophisticated equipment for process control which is in most cases costly and difficult to handle. Currently, there is no technical system on the market that realizes simple process control in high throughput. The novel concept of a microfermentation system described in this work combines a fiber-optic online-monitoring device for microtiter plates (MTPs)--the BioLector technology--together with microfluidic control of cultivation processes in volumes below 1 mL. In the microfluidic chip, a micropump is integrated to realize distinct substrate flow rates during fed-batch cultivation in microscale. Hence, a cultivation system with several distinct advantages could be established: (1) high information output on a microscale; (2) many experiments can be performed in parallel and be automated using MTPs; (3) this system is user-friendly and can easily be transferred to a disposable single-use system. This article elucidates this new concept and illustrates applications in fermentations of Escherichia coli under pH-controlled and fed-batch conditions in shaken MTPs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.