We developed and validated a new accurate model for GFR assessment in cirrhosis, the Royal Free Hospital cirrhosis GFR, using readily available variables; this remains to be tested and incorporated in prognostic scores in patients with cirrhosis. (Hepatology 2017;65:582-591).
BackgroundThe purpose of this study is to identify a method for optimising the administered activity and acquisition time for 18F-FDG PET imaging, yielding images of consistent quality for patients with varying body sizes and compositions, while limiting radiation doses to patients and staff. Patients referred for FDG scans had bioimpedance measurements. They were injected with 3 MBq/kg of 18F up to 370 MBq and scanned on a Siemens Biograph mCT at 3 or 4 min per bed position. Data were rebinned to simulate 2- and 1-min acquisitions. Subjective assessments of image quality made by an experienced physician were compared with objective measurements based on signal-to-noise ratio and noise equivalent counts (NEC). A target objective measure of image quality was identified. The activity and acquisition time required to achieve this were calculated for each subject. Multiple regression analysis was used to identify expressions for the activity and acquisition time required in terms of easily measurable patient characteristics.ResultsOne hundred and eleven patients were recruited, and subjective and objective assessments of image quality were compared for 321 full and reduced time scans. NEC-per-metre was identified as the objective measure which best correlated with the subjective assessment (Spearman rank correlation coefficient 0.77) and the best discriminator for images with a subjective assessment of “definitely adequate” (area under the ROC curve 0.94). A target of 37 Mcount/m was identified. Expressions were identified in terms of patient sex, height and weight for the activity and acquisition time required to achieve this target. Including measurements of body composition in these expressions was not useful. Using these expressions would reduce the mean activity administered to this patient group by 66 MBq compared to the current protocol.ConclusionsExpressions have been identified for the activity and acquisition times required to achieve consistent image quality in FDG imaging with reduced patient and staff doses. These expressions might need to be adapted for other systems and reconstruction protocols.Electronic supplementary materialThe online version of this article (doi:10.1186/s13550-016-0250-3) contains supplementary material, which is available to authorized users.
The Fleming technique outperforms the method currently recommended by the international guidelines, and is simpler as only one equation is required for all patients instead of separate equations for adults and children. We propose that the SS-GFR technique of Fleming replace the methods currently recommended by the international and BNMS guidelines for routine measurement of GFR for expected results greater than 30 ml/min/1.73 m. A thorough system of measurement checks should be implemented for all methods of GFR assessment; the perceived lack of opportunity for quality control checks to be performed on the result of a single-sample measurement is addressed in the companion paper of this study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.