Coronary artery fistulas are rare and are most often diagnosed by echocardiography or by cine-angiocardiography. However, the computed tomography angiography (CTA) of coronary arteries has been gaining ground. The incidence of this disease is very low, with a more frequent occurrence of fistulas originating in the right coronary artery. There is a higher incidence of coronary artery fistulas to right heart chambers, with coronary artery fistulas to the left ventricle (LV) being rare. Treatment can be surgical or percutaneous.This report describes a case of coronary fistula to left ventricle diagnosed by CT angiography of coronary arteries in a hypertensive and asymptomatic 46-year-old male, who was tested positive for ischemia in an exercise test. The CT angiography ruled out coronary obstructive disease, but it revealed a coronary fistula to the left ventricular cavity. Coronary Fistula to the Left Ventricle: Assessed by Computed Tomography Case reportIt refers to a 46-year-old, obese, hypertensive and dyslipidemic male patient. In the physical examination, the patient's heart rate was regular at three different stages and the BP was 160 x 100 mmHg. At the outpatient clinic, in the examination for coronary artery disease (CAD), the patient was asymptomatic.The ischemic test result obtained by means of an exercise test was positive. Therefore, in order to rule out CAD, a CT angiography of the coronary arteries was carried out and it revealed markedly dilated and tortuous coronary arteries, besides a large fistula connecting the anterior descending artery to the right coronary artery and a single confluence for the LV cavity adjacent to the posterior mitral valve leaflet (Figures). MethodsThe examination and clinical history of the patient in the digital archive of images (PACS) were reviewed. The patient's authorization to use the images for a case report was obtained.The equipment used was manufactured by Philips Medical Systems -model Brilliance 16-MDCT.With the patient lying on his back, in respiratory pause (apnea of 15 seconds), in electrocardiographic (ECG) synchronization, 0.75-mm thick tomographic slices of the heart were obtained by using 80 ml of nonionic iodinated contrast (Optiray 350 mg/ml) in an infusion pump at 5 ml/ second, followed by 40 ml of 0.9% saline solution, at the same infusion rate. The images were viewed in the workstation from Philips Medical Systems, Brilliance CT model. Multiplanar reconstructions (MPR), curved multiplanar reconstructions (Curved MPR) and 3D reconstructions with volume rendering technique (VR) were performed (Figures 1 and 2).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.