It is generally assumed that passively fitting superstructures are a prerequisite for long-lasting implant success. In the study presented, the strain development of three-unit implant fixed partial dentures (FPDs) was evaluated at the bone surrounding the implant and on the superstructure using a strain gauge technique. Six groups of three-unit FPDs representing the commonly used techniques of bridge fabrication were investigated with 10 samples each, in order to quantify the influence of impression technique, mode of fabrication and retention mechanism on superstructure fit. Two ITI implants (Straumann, Waldenburg, Switzerland) were anchored in a measurement model according to a real-life patient situation and strain gauges were fixed mesially and distally adjacent to the implants and on the bridge pontics. The developing strains were recorded during cement setting and screw fixation. For statistical analysis, multivariate two sample tests were performed setting the level of significance at P=0.1. None of the investigated bridges revealed a truly passive fit without strains occurring. About 50% of the measured strains were found to be due to impression taking and model fabrication, whereas the remaining 50% were related to laboratory inaccuracies. The two impression techniques used did not reveal any significant differences in terms of precision. Both modes of fixation--i.e. cement and screw retention--provoked equally high stress levels. In the fabrication of screw-retained FPDs, similar results were obtained from the use of burn-out plastic copings and the technique of casting wax moulds to premachined components. Bonding bridge frames onto gold cylinders directly on the implants significantly reduces strain development.
In elderly edentulous patients, the treatment with two interforaminal implants provides evidence of neuromuscular adaptation towards values of healthy dentate. Thus, the known benefits of implant placement such as tissue perseverance and improved function are complemented by improved neuromuscular adaptation.
FPD span and retention mechanism appear to have only a minor influence on strain development in implant FPDs. As implant-supported restorations have proven to be successful over time, the question arises as to whether an "absolute" passive fit is a prerequisite for successful implant restorations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.