Background: Various connections have been machined to improve the fit between the dental abutment and implant. In vivo, the instability created by imprecisely fitting components can cause soft tissue irritation and bacterial colonization of the implant system. The aim of this study was to quantify abutment stability under in vitro force applications. Methods: Abutment stability and fit were quantitatively measured after application of rotational, vertical, and horizontal forces. Findings: The abutment connection held by friction (Friction-Fit) was the only group to have 0°angular rotation. A significantly greater vertical force was required to pull the abutment from the implant for the Friction-Fit connection as compared to all other experimental groups. The abutment connection held by a mechanically locking friction-fit with four grooves (CrossFit) and Friction-Fit demonstrated significantly lower lateral movement as compared to all other connections. The remaining connections evaluated included two hexagon connections that rely on screw placement for abutment fit (Conical + Hex #1 and Conical + Hex #2), one connection with protruding slots to align with recessed channels inside the implant (Conical + 6 Indexing Slots), and an internal connection that allows for abutment indexing every 120°(Internal Tri-Channel). Interpretation: Internal connection geometry influenced the degree of abutment movement. Friction-Fit and CrossFit connections exhibited the lowest rotational and horizontal motions. Significant differences were found between Friction-Fit and CrossFit following the application of a vertical force, with the Friction-Fit requiring a significantly greater pull force to separate the abutment from the implant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.