The aim of this work is to suggest a new diagnostic approach to the "female varicocele syndrome" which utilizes transvaginal ultrasonography. The presence of circular or linear anechogenic structures with a diameter greater than 5 mm, which were found in transverse and oblique sections of the lateral fornices, was indicative of pelvic varices. The vascular nature of these structures was confirmed with the Valsalva's maneuver and in the upright position. The presence of "pelvic varices" was confirmed by retrograde phlebography of the left ovarian vein in 46% of the cases. In such cases the parity was greater than in subjects without "pelvic varices" (chi square = 12.75, p less than 0.001), and the principal symptoms were characterized by pelvic pains and menstrual cycle disorders.
It is still a matter of debate as to which parameters should be used for noninvasive diagnosis of renovascular disease by renal Doppler sonography (RDS). The accuracy of RDS in the detection of renal artery stenosis (RAS) was tested in 95 consecutive, moderate to severe hypertensive patients (I-II World Health Organization [WHO] stages). Reno-aortic ratio (RAR) for peak systolic velocity (PSV) was also calculated to assist in the diagnosis of significant (>50%) RAS. Paired receiver-operating characteristic (ROC) analysis was plotted for evaluating the relationship between sensitivity and specificity for each parameter. In a subset of 57 kidneys, the influence of blood pressure and age on intraparenchymal parameters was evaluated. Measurements of maximal peak systolic velocity (PSV) at the site of stenosis, RAR for PSV, and minimum acceleration index in the main renal artery showed high accuracy (areas under the ROC curve 0.97, 0.88, and 0.80, respectively). Among intraparenchymal parameters, early systolic acceleration showed the best area under the ROC curve (0.90), but provided a low positive predictive value (29%) and was significantly influenced by blood pressure (multiple r=0.56; p=0.001). Pulsatility and resistive indices were found to be less powerful as absolute values, and both significantly influenced by blood pressure and age (multiple r=0.60 and 0.50; p=0.001, p=0.02, respectively). However, interindividual variance of intrarenal indices should be minimized by calculation of side difference, although this procedure would become misleading or impossible in patients with bilateral RAS or a single kidney, respectively. These results support the use of extraparenchymal parameters for noninvasive detection of RAS, and emphasize that intrarenal parameters cannot be considered as absolute values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.