SynopsisTechniques have been developed to measure the acceptance and decay of electrostatic charge on a wide variety of powder coatings. The measurement of the initial charge carried by the powder was affected by the amount of powder deposited. The decay of charge occurred within four time scales: (1) 1 sec, electron loss to air and to the metallic substrate; (2) 1 to 5 sec, electron flow to neutralize induced positive charge; (3) 5 to 100 sec, rapid decay from powder; and (4) 1,OOO to 10,000 sec, very long term decay. Since the decay of charge WM markedly affected by moisture and composition, the decay properties can be controlled by these parameters. A mathematical model was constructed describing the quantitative charge decay during the time period of 100 to 10,000 sec. There was considerable heterogeneity within the powders with regard to charge acceptance and interaction with moisture. These measurement techniques give information concerning electrostatic effects on particle transport, adhesion, and polymer electrostatic behavior which are very important variables in a powder coating proceas.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.