This work concerns the detection of incipient cavitation in pumps using acoustic emission (AE). Three activities have been pursued in this context: (a) the construction of a small-scale rig for the investigation of cavitation detection using AE sensors; (b) the acquisition of data on a 75 kW singlestage centrifugal pump in an industrial test loop under normal running and cavitation conditions; (c) the determination of parameters that could be used for the early diagnosis of cavitation within pumps.In the laboratory-scale apparatus water was pumped around a short loop by a 3 kW centrifugal pump. The flow loop contained a section specifically designed to induce cavitation by means of reducing the pressure level to that of the vapour pressure of the fluid. This apparatus was used to produce a variety of well-controlled cavitation conditions which were useful in determining the suitability of AE for the detection of cavitation.The industrial-scale tests consisted of progressively reducing the net positive suction head in a 75 kW pump while recording the AE signals at various points on the test loop and pump.Results are presented from both laboratory and full-scale tests which demonstrate the feasibility of detecting incipient cavitation using AE in the face of background noise from normal running of the pump. The features of AE which are indicative of cavitation are also seen to change continuously as NPSH is decreased. Thus early detection of cavitation is possible, certainly before any indication is seen on the dynamic head.this end, a small laboratory flow loop has been instru-
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.