Since the introduction and use of automated mineralogy in the mining industry in the 1970s, a variety of companies have developed competing and complementary technologies with a range of capabilities. A historical summary of automated mineralogical systems is shown in Sandmann (2015) [1]. However, all of them were based on electron beam (e-beam) systems (such as scanning electron microscopes (SEM) with energy dispersive X-ray spectrometers (EDS)). Recent advancements in X-ray optics have made it possible to focus an X-ray beam by polycapillary optic to spot sizes less than 20 micrometers, allowing micro-XRF (X-ray fluorescence) to be operated using similar parameters as an e-beam system. The results yield comparable results with traditional automated mineralogical analysis. The advantages and limitations of each technique are discussed, including aspects such as sample preparation, analytical conditions, as well as sample information and processing.One of the main advantages of micro-XRF are sample handling, including simpler sample preparation and the ability to analyze large samples, with an analytical area of up to 20 cm x 16 cm. Furthermore, the X-ray excitation yields significantly lower limits of detection. The e-beam on the other hand offers smaller beam size and interaction volume, providing the advantage of much higher magnification and interactive imaging. Even though both methods are considered as surficial analytical techniques, it should be noted that micro-XRF has a greater depth penetration and hence excitation volume than ebeam analysis, which can lead to differences in results of the special analysis. This can be both advantage and disadvantage depending on the analysis objective. Other differences, especially in spectra, can also be traced back to the different excitation voltages and excitation probabilities. With the X-ray excitation, the acceleration voltage is generally between 35 and 50 kV, whereas with e-beam between 15 and 25 kV. Ionization of X-ray excitation occurs generally with inner electron shells while in contrast electron excitation exhibits ionization of the outer shells. This leads to better sensitivity of lighter elements, below Ca for e-beam excitation, but weaker for heavier elements and higher energy lines.Practically, both systems are equipped with silicon drift detectors (SDD) for EDS analysis, where the ebeam scans by deflection and the micro-XRF moves the stage with the sample. The e-beam acquires an image (field of view) at a given magnification, and can then perform point or area analysis. The micro-XRF has an inbuilt dual magnification co-axial (visible) light microscope to focus on the analytical working distance and obtain mosaic images to define measurement points or areas. For automated mineralogy, there are fundamental parameters that impact on the mineralogical classification and analytical time; these includes (but is not limited too) X-ray beam excitation (kV and µA), detector active area(s) (mm²), pixel spacing (µm), and dwell time (ms).
X-ray fluorescence spectrometry was used in mapping and spot analysis modes, to help identify which elements are useful for understanding the composition of ancient papyrus inks, for 25 papyri from four age groups. We report seven elements (Al, Si, P, S, Ca, Ti, Fe) which provide sufficient contrast to be useful for mapping analysis, and 16 elements (P, S, Cl, K, Ca, V, Mn, Ni, Cu, Zn, Rb, Sr, Nb, Ag, Ba, and Pb) which show significant differences through time. Only one element – Pb – showed sufficient contrast in the thin ink layer to be significantly different when measured on the ink and adjacent papyrus. There is greater complexity in the elemental compositions of the papyrus and ink than can be understood with a study this size and additional work is required to develop and explain the patterns observed here.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.