The thermal-electrical behavior of metallization structures with and without extrusion monitors has been investigated by Finite Element Method (FEM) simulations. The explanation of changes in stress conditions (line temperature, spatial temperature distributions) has been proven to be helpful for the interpretation of electromigration test results.The simulation results of metallization structures with and without extrusion monitors are then compared to corresponding results from Standard Wafer-level Electromigration Accelerated Test (SWEAT) and Isothermal Electromigration tests. The detected failure mode has been verified by optical observation of the metallization structures during and after electromigration stress. The investigations performed on a 0.35um metallization process suggest that it is necessary to use optimized test structure layouts featuring extrusion monitors to obtain accurate electromigration results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.