Summary Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79). Interpretation In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws. Funding National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
We have studied the occurrence of donor site morbidity, cosmesis and overall satisfaction with graft procedure in 76 patients who had undergone iliac crest bone harvesting for anterior cervical discectomy and fusion (ACDF). Totally 24 patients underwent an open procedure and 52 a minimally invasive trephine harvesting method. Although our study demonstrated substantial donor site pain and its effect on ambulation in both groups, this was of limited duration. Two patients, one in each group, suffered long-term pain that was eventually resolved. Totally 8.3% of patients in the open group suffered minor complications and 11.5% in the trephine group. There were two cases of meralgia parasthetica. There were no major complications in either group. There was no statistically significant difference in morbidity between the open and trephine groups. There was a trend towards significance (P = 0.076) for pain at the donor site, with less pain reported by patients who underwent the trephine procedure for harvesting.
Ultrasound-guided RFA has successfully alleviated patients' symptoms of Morton's neuroma in >85% of cases. Only 10% have proceeded to surgical excision in the short term.
Level IV, Case series. See Guidelines for Authors for a complete description of levels of evidence.
There are many methods for analysing wear volume in failed polyethylene acetabular components. We compared a radiological technique with three recognised ex vivo methods of measurement. We tested 18 ultra-high-molecular-weight polyethylene acetabular components revised for wear and aseptic loosening, of which 13 had pre-revision radiographs, from which the wear volume was calculated based upon the linear wear. We used a shadowgraph technique on silicone casts of all of the retrievals and a coordinate measuring method on the components directly. For these techniques, the wear vector was calculated for each component and the wear volume extrapolated using mathematical equations. The volumetric wear was also measured directly using a fluid-displacement method. The results of each technique were compared. The series had high wear volumes (mean 1385 mm(3); 730 to 1850) and high wear rates (mean 205 mm(3)/year; 92 to 363). There were wide variations in the measurements of wear volume between the radiological and the other techniques. Radiograph-derived wear volume correlated poorly with that of the fluid-displacement method, co-ordinate measuring method and shadowgraph methods, becoming less accurate as the wear increased. The mean overestimation in radiological wear volume was 47.7% of the fluid-displacement method wear volume. Fluid-displacement method, coordinate measuring method and shadowgraph determinations of wear volume were all better than that of the radiograph-derived linear measurements since they took into account the direction of wear. However, only radiological techniques can be used in vivo and remain useful for monitoring linear wear in the clinical setting. Interpretation of radiological measurements of acetabular wear must be done judiciously in the clinical setting. In vitro laboratory techniques, in particular the fluid-displacement method, remain the most accurate and reliable methods of assessing the wear of acetabular polyethylene.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.