Nonsteroidal antiinflammatory drugs have been used to obtain preemptive analgesia. We investigated, in this randomized, double-blind study, whether sublingual (s.l.) piroxicam given before was more effective than that given after surgery. Fifty-two patients scheduled for laparoscopic bilateral inguinal hernia repair under general anesthesia were enrolled. Group PRE (25 patients) received 40 mg of piroxicam s.l. 2 h before surgery and a placebo 10 min after surgery. Group POST (27 patients) were treated with a placebo 2 h before surgery and received 40 mg of piroxicam s.l. 10 min after surgery. After an initial dose of 100 mg tramadol IV, patient-controlled analgesia with tramadol was started and recorded. Visual analog scores were assessed in the recovery and at 6, 20, and 30 h postoperatively. Significantly lower visual analog scores were found in group PRE at 6 and 20 h. Significantly smaller cumulative tramadol consumption was observed after 30 h in group PRE. In summary, our findings suggest that preoperative s.l. piroxicam is more effective than the postoperative administration. Because of the low pain scores in both groups, the clinical relevance of these findings is not clear from this study.
A patient developed severe anaphylaxis during irrigation of a wound with rifamycin SV. The temporal relationship between application of rifamycin SV, the positive skin test and basophil activation test for rifamycin SV strongly supported diagnosis of anaphylaxis from the locally applied antibiotic. However, after operation the patient had two anaphylactic reactions with pruritus, urticaria and angio-oedema after routine care by a nurse, and these were probably caused by natural rubber latex. This case report has several messages. First, it is not widely appreciated that topically applied drugs and related compounds can elicit life-threatening anaphylaxis. Second, it illustrates patients can present with more than one allergy. Finally, it provides an opportunity to summarize the applications of flow cytometry-assisted quantification of in vitro activated basophils in diagnosing the cause of anaphylaxis during anaesthesia.
The compliance of three types of breathing tubing commonly used in lung ventilators was measured. The black rubber corrugated tubing commonly used in anaesthetic circuits is too compliant for use in ventilators in intensive care. It is suggested that the international draft standard of compliance for breathing tubes used in lung ventilators should be amended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.