Background: Improving timeliness of pathogen identification is crucial to allow early adaptation of antibiotic therapy and improve prognosis in patients with pneumonia. We evaluated the relevance of a new syndromic rapid multiplex PCR test (rm-PCR) on respiratory samples to guide empirical antimicrobial therapy in adult patients with communityacquired pneumonia (CAP), hospital-acquired pneumonia (HAP), and ventilator-acquired pneumonia (VAP). Methods: This retrospective multicenter study was conducted in four French university hospitals. Respiratory samples were obtained from patients with clinical and radiological signs of pneumonia and simultaneously tested using conventional microbiological methods and the rm-PCR. A committee composed of an intensivist, a microbiologist, and an infectious diseases specialist retrospectively assessed all medical files and agreed on the most appropriate antimicrobial therapy for each pneumonia episode, according to the results of rm-PCR and blinded to the culture results. The rm-PCR-guided antimicrobial regimen was compared to the empirical treatment routinely administered to the patient in standard care. Results: We included 159 pneumonia episodes. Most patients were hospitalized in intensive care units (n = 129, 81%), and episodes were HAP (n = 68, 43%), CAP (n = 54, 34%), and VAP (n = 37, 23%). Conventional culture isolated ≥ 1 microorganism(s) at significant level in 95 (60%) patients. The syndromic rm-PCR detected at least one bacteria in 132 (83%) episodes. Based on the results of the rm-PCR, the multidisciplinary committee proposed a modification of the empirical therapy in 123 (77%) pneumonia episodes. The modification was a de-escalation in 63 (40%), an escalation in 35 (22%), and undetermined in 25 (16%) patients. In microbiologically documented episodes (n = 95), the rm-PCR increased appropriateness of the empirical therapy to 83 (87%), as compared to 73 (77%) in routine care.
Objectives: To evaluate performances of the rapid multiplex PCR assay BioFire FilmArray Pneumonia Panel (FA-PP) for detection of bacterial pathogens and antibiotic resistance genes in sputum, endotracheal aspirate (ETA) and bronchoalveolar lavage (BAL) specimens. Methods: This prospective observational study was conducted in 11 French university hospitals (July to December 2018) and assessed performance of FA-PP by comparison with routine conventional methods. Results: A total of 515 respiratory specimens were studied, including 58 sputa, 217 ETA and 240 BAL. The FA-PP detected at least one pathogen in 384 specimens, yielding an overall positivity rate of 74.6% (384/ 515). Of them, 353 (68.5%) specimens were positive for typical bacteria while eight atypical bacteria and 42 resistance genes were found. While identifying most bacterial pathogens isolated by culture (374/396, 94.4%), the FA-PP detected 294 additional species in 37.7% (194/515) of specimens. The FA-PP demonstrated positive percentage agreement and negative percentage agreement values of 94.4% (95% CI 91.7% e96.5%) and 96.0% (95% CI 95.5%e96.4%), respectively, when compared with culture. Of FA-PP falsenegative results, 67.6% (46/68) corresponded to bacterial species not included in the panel. At the same semi-quantification level (in DNA copies/mL for FA-PP versus in CFU/mL for culture), the concordance rate was 43.4% (142/327) for culture-positive specimens with FA-PP reporting higher semi-quantification of 1 log 10 in 48.6% (159/327) of cases. Interestingly, 90.1% of detected bacteria with 10 6 DNA copies/mL grew significantly in culture. Conclusions: FA-PP is a simple and rapid molecular test that could complement routine conventional methods for improvement of diagnosis accuracy of pneumonia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.