Aim: This study aimed to use the micro-computed tomography to
evaluate the interfacial adaptation and the presence of gaps of NeoMTA
Plus, BioRoot RCS, and MTA in the root-end cavities.
Methodology: Thirty standardized bovine roots measuring 15 mm
in length were selected. Chemical-mechanical preparation was performed
up to instrument #80 and obturation with the cold lateral compaction
technique with cement based on zinc oxide and eugenol. The roots were
kept at 37º C for seven days. Afterward, apicectomy of the apical 3mm
and a root-end filling cavity was performed at 3mm depth. Micro-computed
tomography (micro-CT) was performed to measure the volume of the
retroactivity. The roots were divided by stratified randomization into
three groups according to the retro-end filling material: NeoMTA Plus,
BioRoot RCS, and MTA. A new micro-CT was performed to assess the
presence of voids in the root-end filling material and between it and
the canal wall. One-way ANOVA and Tukey tests were performed using the
BioEstat 4.0 program. Results: There was no difference in the
initial volume values of the root-end cavities (P > 0.05).
After the insertion of root-end filling materials, the most significant
volumes of voids were observed in the NeoMTA Plus group (P <
0.05), with no difference for the BioRoot RCS and MTA Angelus groups (P
> 0.05). Conclusion: Micro-computed tomography
showed that MTA and BioRoot RCS have better interfacial adaptation and
presented fewer number of gaps than NeoMTA Plus when used as root-end
filling materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.