A specific and widely accepted protocol for quality controls in DWI is still lacking. The DWI quality assurance protocol proposed in this study can be applied in order to assess the reliability of DWI-derived indices before tackling single- as well as multicenter studies.
Intensity modulated radiation therapy (IMRT) is increasingly employed in glioblastoma (GBM) treatment. The present work aimed to assess which clinical-dosimetric scenario could benefit the most from IMRT application, with respect to three-dimensional conformal radiation therapy (3D-CRT). The number of organs at risk (OARs) overlapping the planning target volume (PTV) was the parameter describing the clinical-dosimetric pattern. Based on the results, a dosimetric decision criterion to select the most appropriate treatment technique is provided. Seventeen previously irradiated patients were retrieved and re-planned with both 3D-CRT and IMRT. The prescribed dose was 60 Gy/30fx. The cases were divided into 4 groups (4 patients in each group). Each group represents the scenario where 0, 1, 2 or 3 OARs overlapped the target volume, respectively. Furthermore, in one case, 4 OARs overlapped the PTV. The techniques were compared also in terms of irradiated healthy brain tissue. The results were evaluated by paired t-test. IMRT always provided better target coverage (V95%) than 3D-CRT, regardless the clinical-dosimetric scenario: difference ranged from 0.82% (p = 0.4) for scenario 0 to 7.8% (p = 0.02) for scenario 3, passing through 2.54% (p = 0.18) and 5.93% (p = 0.08) for scenario 1 and 2, respectively. IMRT and 3D-CRT achieved comparable results in terms of dose homogeneity and conformity. Concerning the irradiation of serial-kind OARs, both techniques provided nearly identical results. A statistically significant dose reduction to the healthy brain in favor of IMRT was scored. IMRT seems a superior technique compared to 3D-CRT when there are multiple overlaps between OAR and PTV. In this scenario, IMRT allows for a better target coverage while maintaining equivalent OARs sparing and reducing healthy brain irradiation. The results from our patients dataset suggests that the overlap of three OARs can be used as a dosimetric criterion to select which patients should receive IMRT treatment.
Using T(2) MRI, huge variations can be observed in peritumoural oedema, which are probably due to steroid treatment. Using T(1) MRI, brain shifts after surgery and possible progressive enhancing lesions produce substantial differences in CTVs. Our data support the use of post-operative/pre-radiotherapy T(1) weighted MRI for planning purposes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.