PURPOSE: This article aims to report a new clinical finding associated with the wear of scleral lenses. METHODS: Non-contact lens wearer subjects were recruited and fitted with large diameter (18 mm) scleral lenses. Lens was randomly filled with non preserved saline or non preserved carboxymethylcellulose-based artificial tears (Refresh Celluvisc, Allergan, Ca). The sinking of the lens on the nasal and temporal sclera was assessed periodically during a total of 6h00 of wear, with the use of anterior segment coherence tomography (OCT- Optovue, Clarion Technologies, Texas). Images were taken every 30 minutes for the first 2h00, then at 4h00 and 6h00 post-insertion. RESULTS: The nasal side sinks significantly more than the temporal side by 23.0±7.3 μm (F(1,12)=10.043; p=0.008; 95%CI:[7.2 ,38.9]). This difference is significant with time (F=8.757; p<0.001) and there is a side effect (F=10.043; p=0.008). The type of solution does not influence the lens behavior (F=0.250; p=0.626). A new clinical finding was revealed during scan analysis. Conjunctival tissue displacement was seen, under the reverse curve of the scleral lens, shortly after insertion. This conjunctival “inlapse” (CI) was sustained over all the wearing hours. On the nasal quadrant, CI was reduced in height and present in only 8/15 subjects while, in the temporal quadrant, 100% of subjects showed an average CI of 38.39 ± 10.43 μm (t(84)=3.68; p=0.0072; 95%CI[17.64, 59.13]) 30 minutes post insertion followed by a non-significant decrease of 1.97 ± 10.34 μm (t(84)=0.19; p=1.00; 95%CI[-22.52,18.58]) between 30 minutes and 6 hours of wear. CONCLUSION: Nasal sinking is more pronounced as compared with temporal lens sinking. This may explain the occurrence of a new clinical phenomenon identified to happen shortly after lens insertion, under the reverse curve of a scleral lens. In fact, CI happens mostly on the temporal quadrant, where more space is available for the conjunctival tissue to move. This finding suggests that conjunctival tissue reacts to scleral lens wear, not only in the inferior quadrant, where conjunctival prolapse is known to occur, but in every other one as well.
PurposeThis study aims to determine if lens or tear fluid reservoir thicknesses (LT/FRT) may influence the presence of residual astigmatism and participant’s visual acuity. MethodsThe study was a randomized, non-dispensing, prospective study. Empirically and randomly chosen participants were fitted with 4 combinations (350 and 250 um LT fitted with 250 and 350 um FRT) of 16 mm diameter scleral lenses, designed using a corneo-scleral profiler software (sMap 3D, Visionary Optics, US). Lenses haptics were kept spherical for all lenses. They were evaluated under a slit lamp, anterior segement OCT (objective fluid reservoir and lens thicknesses), topography over lenses and aberrometry, after 30 minutes of lens wear. Spherico-cylindrical refraction and logMar acuity were also assessed. ResultsStudy population was composed of 24 participants aged 24.2 + 4.7 years old. Baseline refractive error was -2.3 + 1.6 D with -0.48 + 0.26 D of astigmatism. In vivo (OCT) lens A was 344.1 ± 15.4 um thick, fitted with a vault of 213.6 ± 42.4 um; Lens B was 346.2 ± 12.5/327.2 ± 44.8; Lens C was 260.3 ± 17.7/214.0 ± 40.6 um and Lens D was 262.2 ±13.2/330.8 ± 52.0 respectively. All lenses were found similarly decentered inferiorly by 0.10 to 0.15 um. BCVA was −0.32 + 0.08 (A), −0.21 + 0.10 (B), −0.28 + 0.08 (C), and −0.14 + 0.10 (D), compared to −0.25 + 0.08 (A), −0.11 + 0.10 (B), −0.23 + 0.06 (C), and −0.05 + 0.12 (D) when sphere only was compensated. Residual refractive astigmatism (RA = -0.50 to -0.75D) is found significantly higher based on the FRT (F=9.560; p=0.037) and not LT(F=0.429; p=0.522). There is no correlation be-tween RA and over-k readings (Lens A r=-0.078, p=0.773; Lens B r=−0.073, p=0.788; Lens C r=−0.345, p=0.171; Lend D r=0.019, p=0.944). Higher order aberrations, mostly vertical coma, were found clinically significant but not statistically different between lenses (A= 0.350 + 0.032; B=0.382 + 0.053, C=0.329 + 0.044 and D=0.385+ 0.062; p=0.776) ConclusionThis study proves that low level of RA may be found when scleral lenses are fitted on normal corneas. Its occurrence is related to the presence of high-order aberrations and less likely to lens flexure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.