Aims: To examine the killing efficiency of UV KrCl excilamp against Gram‐positive and Gram‐negative bacteria.
Methods and Results: Vegetative cells of Bacillus cereus, Bacillus subtilis, Escherichia coli O157:H7, Staphylococcus aureus and Streptococcus pyogenes at initial populations from 102 to 107 colony‐forming units (CFU) ml−1 were treated by KrCl excilamp in sterile Ringer’s solution with and without H2O2. The number of viable cells was determined using spread plating techniques and nutrient agar method with subsequent incubation at 28°C or 37°C for 24 h. At estimated populations of 102–105 CFU ml−1E. coli O157:H7 and Staph. aureus were the most sensitive and showed 100% disinfection within 15 s (29·2 mJ cm−2). Bacillus subtilis was more sensitive to UV treatment than B. cereus. The UV/H2O2 inactivation rate coefficients within this population range were two times higher than those observed for UV treatment alone. No effect of H2O2 was observed at 107 CFU ml−1 for Bacillus sp. and Strep. pyogenes.
Conclusions: The narrow‐band UV radiation at 222 nm was effective in the rapid disinfection of bacteria in aqueous suspensions.
Significance and Impact of the Study: KrCl excilamps represent UV sources which can be applied for disinfection of drinking water in advanced oxidation processes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.