Background The aim of this retrospective monocentric study was to investigate the clinical efficacy of percutaneous reduction and screw fixation without bone grafting in Sanders Type-II and Type-III displaced intra-articular calcaneal fractures (DIACFs). Methods The medical records of calcaneal fractures patients who were admitted to our department from January 2018 to January 2020 were retrospectively reviewed, and those meeting the inclusion criteria were fnally included for analysis. All patients were treated with percutaneous reduction and screw fixation, and no patients received bone grafting. The radiologic parameters evaluated included the BÖhler angle and the calcaneal height. In addition, the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scores, Maryland Foot Score (MFS), and visual analog scale (VAS) score were determined. Results Thirty-eight patients with Sanders Type-II and Type-III DIACFs were finally included, including 30 males and 8 females aged 21 to 61 years [(42.6 ± 9.6) years]. According to the Essex-Lopresti classification, 27 of the fractures were the tongue type, and 11 were the joint compression type. According to the Sanders classification, 27 of the fractures were type II, and 11 were type III. Immediately postoperatively, the calcaneal height had recovered to 39.8 ± 2.1 mm, the BÖhler angle had recovered from 4.2° ± 13.6° preoperatively to 27.2° ± 3.4° (P = 0.000). All patients were followed up for 18–42 months [(25.2 ± 9.5) months]. All fractures healed. No differences were found in the outcome measures six-months postoperatively (BÖhler angle, p = 0.24; calcaneal height, p = 0.82) or at final follow-up (BÖhler angle, p = 0.33; calcaneal height, p = 0.28) compared to the immediately postoperative values. At the final follow-up, the AOFAS score was 91.7 ± 7.4 points, with an excellent and good rate of 92.1%; the MFS was 90.3 ± 7.8 points, with an excellent and good rate of 92.1%; and the VAS score was 2.2 ± 1.5 points. None of the patients had incision complications, and one patient developed traumatic arthritis. Conclusion Percutaneous reduction and screw fixation without bone grafting in Sanders Type-II and Type-III DIACFs can achieve good recovery and maintenance of the BÖhler angle and calcaneal height. Moreover, it has the advantage of a low complication rate.
Objective To compare the clinical efficacy of minimally invasive percutaneous treatment by ligamentotaxis with traditional open reduction and internal fixation in the treatment of Essex-Lopresti joint depression-type displaced intra-articular calcaneal fractures (DIACFs). Methods The medical records of patients with calcaneal fractures admitted to our department from January 2016 to December 2020 were retrospectively analyzed, and patients who met the inclusion criteria were finally included for analysis. Twenty-one patients underwent minimally invasive percutaneous treatment by ligamentotaxis (Group A), while eighteen patients were treated by traditional open reduction and internal fixation through an extended lateral approach (Group B). The preoperative waiting time, operative time, hospital stay, radiologic parameters (calcaneal height, width, length, Böhler angle and Gissane angle), American Foot and Ankle Surgery Association (AOFAS) hindfoot scores, Maryland Foot Score (MFS), visual analogue scale (VAS), and incidence of complications of the included patients were all recorded and analysed. Results Thirty-nine patients with Essex-Lopresti joint depression type DIACFs were finally included. According to the Sanders classification, 22 were type II, 12 were type III and 5 were type IV. The preoperative waiting time and the hospital stay of Group A were 3.7 ± 1.6 d and 7.2 ± 1.7 d, respectively, which were significantly shorter than those of Group B (6.9 ± 2.0 d and 12.4 ± 1.5 d) (P < 0.05). There was no significant difference in the operative time between the two groups (88.8 ± 9.8 min vs. 91.3 ± 12.1 min; P > 0.05). No significant differences were shown in the radiological parameters (calcaneal height, width, length, Böhler angle and Gissane angle) or the satisfactory rate of joint surface reduction (SRJSR) of the two groups immediately postoperatively. All patients were followed up for 14 to 56 months [(30.2 ± 10.4) months]. All fractures healed. At the final follow-up, there were no significant differences in the radiological parameters or the SRJSR between the two groups (P > 0.05). No significant differences were shown in the AOFAS scores, MFS or VAS scores between the two groups [(89.5 ± 8.2) vs. (89.4 ± 9.0), P > 0.05; (87.5 ± 8.3) vs. (86.3 ± 8.9), P > 0.05; and (2.1 ± 1.2) vs. (2.2 ± 1.2), P > 0.05]. The excellent and good rates of the AOFAS scores and MFS were 90.5% and 85.7%, respectively, in Group A and 88.9% and 88.9%, respectively, in Group B (P > 0.05). Four patients experienced wound complications, including 1 superficial incision infection, 2 skin necrosis around the incision edge and 1 deep infection in Group B, while there were no wound complications in Group A (P < 0.05). One patient in each group suffered traumatic arthritis (P > 0.05). Conclusions In the assessment of Essex-Lopresti joint depression type DIACFs, minimally invasive percutaneous treatment by ligamentotaxis has similar clinical outcomes to traditional open reduction and internal fixation through an extended lateral approach. However, the former has the advantages of shorter preoperative waiting time and hospital stay, and lower incidence of incision complications.
Background: Because of the fragment size and inferior location of the fracture lines, options are lacking for internal fixation to treat avulsion fractures of the tip of the lateral malleolus. Because the anatomical architecture of the distal malleolus is similar to that of the distal ulna metaphysis, the purpose of this study was to assess the effectiveness of 2.0-mm locking compression plate distal ulna hook plates in treating avulsion fractures of the tip of the lateral malleolus.Methods: Given the characteristics of the 2.0-mm locking compression plate distal ulna hook plate, cases in which the distance between the fracture lines and the distal end of the tip of the lateral malleolus was less than 6 mm were excluded. Seventeen patients (AO Foundation/Orthopaedic Trauma Association (AO/OTA) 44A fractures, 13 males, 4 females, median age 41 years range 18-73 years) with avulsion fractures of the tip of the lateral malleolus were included. All patients were treated with fixation of the fragment to the fibula using a 2.0-mm locking compression plate distal ulna hook plate. Clinical and radiological follow-up visits were conducted at 6 weeks and 3, 6, 12 and 24 months after the operation. Results: The mean American Orthopedic Foot and Ankle Society Ankle-Hindfoot score of the patients was 97.06±1.92 (range 94 to 100) at the 12-month postoperative follow-up and 97.71±1.54 (range 96 to 100) at the 24-month postoperative follow-up. The mean Karlsson score was 94.18±3.88 (range 90 to 100) at the 12-month postoperative follow-up and 96.43±2.34 (range 95 to 100) at the 24-month postoperative follow-up. Nonunion was not noted; 6 patients complained of lateral malleolar discomfort and foreign body sensation, and 3 of these patients underwent a hardware removal operation at 12 months postoperatively. All patients were clinically and radiographically stable.Conclusion: A 2.0-mm locking compression plate distal ulna hook plate achieved stable and anatomically suitable fixation and should be considered as an alternative treatment for avulsion fractures of the tip of the lateral malleolus.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.