Background: The aim of this study was to gain a deeper understanding of the gender differences in knee osteoarthritis (OA) by evaluating the differences in gait spatio-temporal parameters and the differences in pain, quality of life and function between males and females suffering from knee OA.
BackgroundThe purpose of the current study was to examine objective and subjective differences between three severity groups of ankle fractures patients compared to healthy controls.MethodsThis was a case-controlled study. 92 patients with an ankle fracture injury of which 41 patients were eligible to participate in the study. 72 healthy people served as controls. All patients underwent a computerized gait test, completed self-assessment questionnaires (The Foot and Ankle Outcome Score (FAOS) and the SF-36), evaluated with the American Foot and Ankle Score (AOFAS) form and completed the 6-min walk test. The control group performed a computerized gait test and completed the SF-36 health survey.ResultsAll ankle fracture patients presented compromised gait patterns and limb symmetry compared to controls (p < 0.05). Ankle fracture patients also had lower SF-36 scores compared to controls (p < 0.05). Significant differences were found between the unimalleolar group compared to the bimalleolar and trimalleolar groups in most parameters, except for the FAOS scores. There were no significant differences between the bimalleolar fracture group and the trimalleolar fracture groups.ConclusionsAlthough all fracture severity classification groups presented a compromised gait pattern and worse clinical symptoms compared to controls, it seems that patients with a unimalleolar fracture is a different group compared to bimalleolar and trimalleolar fracture. Furthermore, it seems that bimalleolar fracture and trimalleolar fracture affect the gait pattern and clinical symptoms to an equal extent, at least in the short-term.Trial registrationNCT01127776.
BackgroundGait metric alterations have been previously reported in patients suffering from chronic ankle instability (CAI). Previous studies of gait in this population have been comprised of relatively small cohorts, and the findings of these studies are not uniform. The objective of the present study was to examine spatiotemporal gait metrics in patients with CAI and examine the relationship between self-reported disease severity and the magnitude of gait abnormalities.MethodsForty-four patients with CAI were identified and compared to 53 healthy controls. Patients were evaluated with spatiotemporal gait analysis via a computerized mat and with the Short Form (SF) - 36 health survey.ResultsPatients with CAI were found to walk with approximately 16% slower walking velocity, 9% lower cadence and approximately 7% lower step length. Furthermore, the base of support, during walking, in the CAI group was approximately 43% wider, and the single limb support phase was 3.5% shorter compared to the control group.All of the SF-36 8-subscales, as well as the SF-36 physical component summary and SF-36 mental component summary, were significantly lower in patients with CAI compared to the control group. Finally, significant correlations were found between most of the objective gait measures and the SF-36 mental component summary and SF-36 physical component summary.ConclusionsThe results outline a gait profile for patients suffering from CAI. Significant differences were found in most spatiotemporal gait metrics. An important finding was a significantly wider base of support. It may be speculated that these gait alterations may reflect a strategy to deal with imbalance and pain. These findings suggest the usefulness of gait metrics, alongside with the use of self-evaluation questionnaires, in assessing disease severity of patients with CAI.
BackgroundThe purpose of this study was to examine the differences in gait profile between patients with knee osteoarthritis (OA) and healthy control and to create motion characteristics that will differentiate between them.MethodsTwenty three patients diagnosed with knee OA and 21 healthy matched controls underwent a gait test using a sensor system (gaitWALK). Gait parameters evaluated were: stride duration, knee flexion range of motion (ROM) in swing and stance. T-Test was used to evaluate significant differences between groups (P < 0.05).ResultsPatients with knee OA had significant lower knee flexion ROM (10.3° ± 4.0°) during stance than matched controls (18.0° ± 4.0°) (p < 0.001). Patients with knee OA had significant lower knee flexion ROM (54.8° ± 5.5°) during swing than matched controls (61.2° ± 6.1) (p = 0.003). Patients with knee OA also had longer stride duration (1.12 s ± 0.09 s) than matched controls (1.06 s ± 0.11 s), but this was not statistically significant (p = 0.073). Motion characteristics differentiate between a patient with knee OA and a healthy one with a sensitivity of 0.952 and a specificity of 0.783.ConclusionsSignificant differences were found in the gait profile of patients with knee OA compared to matched control and motion characteristics were identified. This test might help clinicians identify and evaluate a knee problem in a simple gait test.
BackgroundPrevious studies have shown the effect of a unique therapy with a non-invasive biomechanical foot-worn device (AposTherapy) on Caucasian western population suffering from knee osteoarthritis. The purpose of the current study was to evaluate the effect of this therapy on the level of symptoms and gait patterns in a multi-ethnic Singaporean population suffering from knee osteoarthritis.MethodsFifty-eight patients with bilateral medial compartment knee osteoarthritis participated in the study. All patients underwent a computerized gait test and completed two self-assessment questionnaires (WOMAC and SF-36). The biomechanical device was calibrated to each patient, and therapy commenced. Changes in gait patterns and self-assessment questionnaires were reassessed after 3 and 6 months of therapy.ResultsA significant improvement was seen in all of the gait parameters following 6 months of therapy. Specifically, gait velocity increased by 15.9%, step length increased by 10.3%, stance phase decreased by 5.9% and single limb support phase increased by 2.7%. In addition, pain, stiffness and functional limitation significantly decreased by 68.3%, 66.7% and 75.6%, respectively. SF-36 physical score and mental score also increased significantly following 6 months of therapy (46.1% and 22.4%, respectively) (P < 0.05 for all parameters).ConclusionsSingaporean population with medial compartment knee osteoarthritis demonstrated improved gait patterns, reported alleviation in symptoms and improved function and quality of life following 6 months of therapy with a unique biomechanical device.Trial registrationRegistration number NCT01562652.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.