We have developed a generic approach to engineer tubular micro‐/nanostructures out of many different materials (see figure) with tunable diameters and lengths by precisely releasing and rolling up functional nanomembranes on polymers. The technology spans across different scientific fields ranging from photonics to biophysics and we demonstrate optical ring resonators, magneto‐fluidic sensors, remotely controlled microjets and 2D confined channels for cell growth guiding.
Strain-engineered microtubes with an inner catalytic surface serve as self-propelled microjet engines with speeds of up to approximately 2 mm s(-1) (approximately 50 body lengths per second). The motion of the microjets is caused by gas bubbles ejecting from one opening of the tube, and the velocity can be well approximated by the product of the bubble radius and the bubble ejection frequency. Trajectories of various different geometries are well visualized by long microbubble tails. If a magnetic layer is integrated into the wall of the microjet engine, we can control and localize the trajectories by applying external rotating magnetic fields. Fluid (i.e., fuel) pumping through the microtubes is revealed and directly clarifies the working principle of the catalytic microjet engines.
Strain-engineered tubular microjet engines with various geometric dimensions hold interesting autonomous motions in an aqueous fuel solution when propelled by catalytic decomposition of hydrogen peroxide to oxygen and water. The catalytically-generated oxygen bubbles expelled from microtubular cavities propel the microjet step by step in discrete increments. We focus on the dynamics of our tubular microjets in one step and build up a body deformation model to elucidate the interaction between tubular microjets and the bubbles they produce. The average microjet velocity is calculated analytically based on our model and the obtained results demonstrate that the velocity of the microjet increases linearly with the concentration of hydrogen peroxide. The geometric dimensions of the microjet, such as length and radius, also influence its dynamic characteristics significantly. A close consistency between experimental and calculated results is achieved despite a small deviation due to the existence of an approximation in the model. The results presented in this work improve our understanding regarding catalytic motions of tubular microjets and demonstrate the controllability of the microjet which may have potential applications in drug delivery and biology.
Microtubular optical microcavities from rolled-up ring resonators with subwavelength wall thicknesses have been fabricated by releasing prestressed SiO/SiO(2) bilayer nanomembranes from photoresist sacrificial layers. Whispering gallery modes are observed in the photoluminescence spectra from the rolled-up nanomembranes, and their spectral peak positions shift significantly when measurements are carried out in different surrounding liquids, thus indicating excellent sensing functionality of these optofluidic microcavities. Analytical calculations as well as finite-difference time-domain simulations are performed to investigate the light confinement in the optical microcavities numerically and to describe the experimental mode shifts very well. A maximum sensitivity of 425 nm/refractive index unit is achieved for the microtube ring resonators, which is caused by the pronounced propagation of the evanescent field in the surrounding media due to the subwavelength wall thickness design of the microcavity. Our optofluidic sensors show high potential for lab-on-a-chip applications, such as real-time bioanalytic systems.
Transparent oxide rolled-up microtube arrays were constructed on Si substrates by the deposition of a pre-stressed oxide layer on a patterned photoresist sacrificial layer and the subsequent removal of this sacrificial layer. These microtubes as well as their arrays can be well positioned onto a chip for further applications, while their dimensions (e.g. length, diameter and wall thickness) are controlled by tunable parameters of the fabrication process. Due to the unique tubular structure and optical transparency, such rolled-up microtubes can serve as well-defined two-dimensionally (2D) confined cell culture scaffolds. In our experiments, yeast cells exhibit different growth behaviors (i.e. their arrangement) in microtubes with varied diameters. In an extremely small microtube the yeast cell becomes highly elongated during growth but still survives. Detailed investigations on the behavior of individual yeast cells in a single microtube are carried out in situ to elucidate the mechanical interaction between microtubes and the 2D confined cells. The confinement of tubular channels causes the rotation of cell pairs, which is more pronounced in smaller microtubes, leading to different cellular assemblies. Our work demonstrates good capability of rolled-up microtubes for manipulating individual and definite cells, which promises high potential in lab-on-a-chip applications, for example as a bio-analytic system for individual cells if integrated with sensor functionalities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.