Though the Platform Screen Door System (PSD) has received a positive evaluation and is installed in all the Urban Railroad platforms, PSD is not installed in the Intercity Railroad platforms. The limitation of PSD in the Intercity Railroad platforms is due to the fact that first, various types of trains such as KTX, Saemaeul, Mugunghwa, and Nuriro stop at the platforms and their locations of the doors are different and secondly, they are not operated under ATO (automatic train operation). RPSD system currently under research and development, on the other hand, is based on the improved door that slides up and down and can be installed in any Intercity Railroad platform regardless of the length of the train, the location of doors, and the number of doors. This study considers the mechanism of RPSD, develops a manual open/close algorithm, and evaluates the function of RPSD. The results show that the manual open/close algorithm achieves a significant improvement in efficiency when provided with power supply.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citationsโcitations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.