beta-Adrenoceptor antagonists (beta-blockers) provide multiple benefits to patients with coronary artery disease. The 2001 American Heart Association and American College of Cardiology (AHA/ACC) guidelines for secondary prevention of myocardial infarction (MI) recommend initiating beta-adrenoceptor blockade in all post-MI patients and continuing therapy indefinitely. Atenolol and metoprolol have been shown to decrease vascular mortality in the acute-MI period. In the post-MI period timolol provided a 39% reduction in mortality in the Norwegian Multicenter Study group and propranolol was associated with a 26% reduction in mortality in BHAT (Beta-blocker Heart Attack Trial). beta-Adrenoceptor antagonist therapy results in reduction of myocardial oxygen demand and is therefore also effective for the treatment of angina pectoris. In CAST (Cardiac Arrhythmia Suppression Trial) beta-adrenoceptor antagonist therapy was associated with a significant reduction in arrhythmic death or cardiac arrest. In the post-MI amiodarone trials EMIAT (European Myocardial Infarct Amiodarone Trial) and CAMIAT (Canadian Amiodarone Myocardial Infarction Trial) there was a mortality benefit and decreased arrhythmic death in patients who received both amiodarone and beta-adrenoceptor antagonist therapy, compared with patients receiving amiodarone therapy alone. In the post-MI defibrillator (implantable cardioverter defibrillator [ICD]) trials, AVID (Antiarrhythmic Versus Implantable Defibrillator) and MUSTT (Multicenter Unsustained Tachycardia Trial), beta-adrenoceptor antagonist therapy was independently associated with improved overall survival. The exception was the ICD patients in MUSTT, and the benefit was attenuated in the amiodarone and ICD patients in AVID.AHA/ACC guidelines recommend the use of beta-adrenoceptor antagonists in all patients with symptomatic left ventricular dysfunction, based on several large, controlled heart failure trials. Extended-release metoprolol succinate reduced all-cause mortality by 34% in MERIT-HF (Metoprolol Controlled-Release/Extended-Release Randomized Intervention Trial in Heart Failure). Bisoprolol was associated with a 34% mortality benefit in CIBIS-II (Cardiac Insufficiency Bisoprolol Study II) and carvedilol was associated with a 35% mortality reduction in the COPERNICUS (Carvedilol Prospective Randomized Cumulative Survival) trial. beta-Adrenoceptor antagonists reduce perioperative mortality in patients undergoing cardiac as well as non-cardiac surgery; however, they remain underutilised. Contraindications to beta-adrenoceptor antagonist therapy include severe bradycardia, high-grade atrioventricular block, marked sinus node dysfunction and acute exacerbations of heart failure. Many of the perceived adverse effects of beta-adrenoceptor antagonists have not been substantiated by large clinical trials.beta-Adrenoceptor antagonists differ with regard to receptor selectivity, receptor affinity, lipophilicity and intrinsic sympathomimetic activity. Beneficial properties of beta-adrenoceptor antagonist...
Background The ideal treatment of inappropriate sinus tachycardia (IST) and postural orthostatic tachycardia syndrome (POTS) still needs to be defined. Medical treatments yield suboptimal results. Endocardial catheter ablation of the sinus node (SN) may risk phrenic nerve damage and open-heart surgery may be accompanied by unjustified invasive risks. Methods We describe our first multicenter experience of 255 consecutive patients (235 females, 25.94 ± 3.84 years) having undergone a novel SN sparing hybrid thoracoscopic ablation for drug-resistant IST (n = 204, 80%) or POTS (n = 51, 20%). As previously described, the SN was identified with 3D mapping. Surgery was performed through three 5-mm ports from the right side. A minimally invasive approach with a bipolar radiofrequency clamp was used to ablate targeted areas while sparing the SN region. The targeted areas included isolation of the superior and the inferior caval veins, and a crista terminalis line was made. All lines were interconnected. Results Normal sinus rhythm (SR) was restored in all patients at the end of the procedure. All patients discontinued medication during the follow-up. After a blanking period of 6 months, all patients presented stable SR. At a mean of 4.07 ± 1.8 years, normal SN reduction and chronotropic response to exercise were present. In the 51 patients initially diagnosed with POTS, no syncope occurred. During follow-up, pericarditis was the most common complication (121 patients: 47%), with complete resolution in all cases. Pneumothorax was observed in 5 patients (1.9%), only 3 (1.1%) required surgical drainage. Five patients (1.9%) required a dual-chamber pacemaker due to sinus arrest > 5 s. Conclusions Preliminary results of this multicenter experience with a novel SN sparing hybrid ablation of IST/POTS, using surgical thoracoscopic video-assisted epicardial ablation combined with simultaneous endocardial 3D mapping may prove to be an efficient and safe therapeutic option in patients with symptomatic drug-resistant IST and POTS. Importantly, in our study, all patients had a complete resolution of the symptoms and restored normal SN activity.
Background: The leadless Micra transcatheter-pacing system (Micra-TPS) is implanted via a femoral approach using a 27-French introducer sheath. The Micra Transcutaneous Pacing Study excluded patients with inferior vena cava (IVC) filters. Objective: To examine the feasibility and safety of Micra-TPS implantation through an IVC filter. Methods: This multicenter retrospective study included patients with an IVC filter who underwent a Micra-TPS implantation. Data for clinical and IVC filter characteristics, preprocedure imaging, and procedural interventions were collected. The primary outcome was a successful leadless pacemaker (LP) implantation via a femoral approach in the presence of an IVC filter. Periprocedural and delayed clinical complications were also evaluated. Results: Of the 1528 Micra-TPS implants attempted, 23 patients (1.5%) had IVC filters. The majority (69.6%) of IVC filters were permanent. Six (26.1%) patients underwent preprocedural imaging to assess for filter patency. One patient's filter was retrieved before LP implantation. The primary outcome was achieved in 21 of 22 patients (95.5%) with an existing IVC filter. An occluded IVC precluded LP implantation in one patient. Difficulty advancing the stiff guidewire or the 27-Fr sheath was encountered in five patients. These cases required repositioning of the wire (n = 2), gradual sheath upsizing (n = 2), or balloon dilation of the filter (n = 1). Postprocedure fluoroscopy revealed intact filters in all cases. During a median 6-month follow-up, there were no clinical complications related to the filter or the Micra-TPS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.