Graph theory has evolved into a useful tool for studying complex brain networks inferred from a variety of measures of neural activity, including fMRI, DTI, MEG and EEG. In the study of neurological disorders, recent work has discovered differences in the structure of graphs inferred from patient and control cohorts. However, most of these studies pursue a purely observational approach; identifying correlations between properties of graphs and the cohort which they describe, without consideration of the underlying mechanisms. To move beyond this necessitates the development of computational modeling approaches to appropriately interpret network interactions and the alterations in brain dynamics they permit, which in the field of complexity sciences is known as dynamics on networks. In this study we describe the development and application of this framework using modular networks of Kuramoto oscillators. We use this framework to understand functional networks inferred from resting state EEG recordings of a cohort of 35 adults with heterogeneous idiopathic generalized epilepsies and 40 healthy adult controls. Taking emergent synchrony across the global network as a proxy for seizures, our study finds that the critical strength of coupling required to synchronize the global network is significantly decreased for the epilepsy cohort for functional networks inferred from both theta (3–6 Hz) and low-alpha (6–9 Hz) bands. We further identify left frontal regions as a potential driver of seizure activity within these networks. We also explore the ability of our method to identify individuals with epilepsy, observing up to 80 predictive power through use of receiver operating characteristic analysis. Collectively these findings demonstrate that a computer model based analysis of routine clinical EEG provides significant additional information beyond standard clinical interpretation, which should ultimately enable a more appropriate mechanistic stratification of people with epilepsy leading to improved diagnostics and therapeutics.
Recent clinical work has implicated network structure as critically important in the initiation of seizures in people with idiopathic generalized epilepsies. In line with this idea, functional networks derived from the electroencephalogram (EEG) at rest have been shown to be significantly different in people with generalized epilepsy compared to controls. In particular, the mean node degree of networks from the epilepsy cohort was found to be statistically significantly higher than those of controls. However, the mechanisms by which these network differences can support recurrent transitions into seizures remain unclear. In this study, we use a computational model of the transition into seizure dynamics to explore the dynamic consequences of these differences in functional networks. We demonstrate that networks with higher mean node degree are more prone to generating seizure dynamics in the model and therefore suggest a mechanism by which increased mean node degree of brain networks can cause heightened ictogenicity.
Epilepsy is a neurological disorder characterized by sudden, often unexpected transitions from normal to pathological behavioral states called epileptic seizures. Some of these seizures are accompanied by uncontrolled, often rhythmic movements of body parts when seizure activity propagates to brain areas responsible for the initiation and control of movement. The dynamics of these transitions is, in general, unknown. As a consequence, individuals have to be monitored for long periods in order to obtain sufficient data for adequate diagnosis and to plan therapeutic strategy. Some people may require long-term care in special units to allow for timely intervention in case seizures get out of control. Our goal is to present a method by which a subset of motor seizures can be detected using only remote sensing devices (i.e., not in contact with the subject) such as video cameras. These major motor seizures (MMS) consist of clonic movements and are often precursors of generalized tonic-clonic (convulsive) seizures, sometimes leading to a condition known as status epilepticus, which is an acute life-threatening event. We propose an algorithm based on optical flow, extraction of global group transformation velocities, and band-pass temporal filtering to identify occurrence of clonic movements in video sequences. We show that for a validation set of 72 prerecorded epileptic seizures in 50 people, our method is highly sensitive and specific in detecting video segments containing MMS with clonic movements.
SummaryObjectiveAutomated seizure detection and alarming could improve quality of life and potentially prevent sudden, unexpected death in patients with severe epilepsy. As currently available systems focus on tonic–clonic seizures, we want to detect a broader range of seizure types, including tonic, hypermotor, and clusters of seizures.MethodsIn this multicenter, prospective cohort study, the nonelectroencephalographic (non‐EEG) signals heart rate and accelerometry were measured during the night in patients undergoing a diagnostic video‐EEG examination. Based on clinical video‐EEG data, seizures were classified and categorized as clinically urgent or not. Seizures included for analysis were tonic, tonic–clonic, hypermotor, and clusters of short myoclonic/tonic seizures. Features reflecting physiological changes in heart rate and movement were extracted. Detection algorithms were developed based on stepwise fulfillment of conditions during increases in either feature. A training set was used for development of algorithms, and an independent test set was used for assessing performance.ResultsNinety‐five patients were included, but due to sensor failures, data from only 43 (of whom 23 patients had 86 seizures, representing 402 h of data) could be used for analysis. The algorithms yield acceptable sensitivities, especially for clinically urgent seizures (sensitivity = 71–87%), but produce high false alarm rates (2.3–5.7 per night, positive predictive value = 25–43%). There was a large variation in the number of false alarms per patient.SignificanceIt seems feasible to develop a detector with high sensitivity, but false alarm rates are too high for use in clinical practice. For further optimization, personalization of algorithms may be necessary.
Seizure detection devices can improve epilepsy care, but wearables are not always tolerated. We previously demonstrated good performance of a real‐time video‐based algorithm for detection of nocturnal convulsive seizures in adults with learning disabilities. The algorithm calculates the relative frequency content based on the group velocity reconstruction from video‐sequence optical flow. We aim to validate the video algorithm on nocturnal motor seizures in a pediatric population. We retrospectively analyzed the algorithm performance on a database including 1661 full recorded nights of 22 children (age = 3‐17 years) with refractory epilepsy at home or in a residential care setting. The algorithm detected 118 of 125 convulsions (median sensitivity per participant = 100%, overall sensitivity = 94%, 95% confidence interval = 61%‐100%) and identified all 135 hyperkinetic seizures. Most children had no false alarms; 81 false alarms occurred in six children (median false alarm rate [FAR] per participant per night = 0 [range = 0‐0.47], overall FAR = 0.05 per night). Most false alarms (62%) were behavior‐related (eg, awake and playing in bed). Our noncontact detection algorithm reliably detects nocturnal epileptic events with only a limited number of false alarms and is suitable for real‐time use.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.