Optimizing the timing and safety for the placement of a tracheostomy in infants with bronchopulmonary dysplasia (BPD) has not been determined. The purpose of the present study was to describe the data from a single institution about the efficacy and safety of tracheostomy placement in infants with BPD needing long-term respiratory support. We established a service line for the comprehensive care of infants with BPD and we collected retrospective clinical data from this service line. We identified patients that had a trachostomy placed using the local Vermont-Oxford database, and obtained clinical data from chart reviews. We identified infants who had a tracheostomy placed for the indication of severe BPD only. Safety and respiratory efficacy was assessed by overall survival to discharge and the change in respiratory supportive care from just before placement to 1-month post-placement. Twenty-two patients (750 ± 236 g, 25.4 ± 2.1 weeks gestation) had a tracheostomy placed on day of life 177 ± 74 which coincided with a post-conceptual age of 51 ± 10 weeks. At placement these infants were on high settings to support their lung disease. The mean airway pressure (MAP) was 14.3 ± 3.3 cmH(2) O, the peak inspiratory pressure was 43.7 ± 8.0 cmH(2) O, and the FiO(2) was 0.51 ± 0.13. The mean respiratory severity score (MAP × FiO(2) ) 1 month after tracheostomy was significantly (P = 0.03) lower than prior to tracheostomy. Survival to hospital discharge was 77%. All patients with tracheostomies that survived were discharged home on mist collar supplemental oxygen. In conclusion, the high survival rate in these patients with severe BPD and the decreased respiratory support after placement of a tracheostomy suggests that high ventilatory pressures should not be a deterrent for placement of a tracheostomy. Future research should be aimed at determining optimal patient selection and timing for tracheostomy placement in infants with severe BPD.
RSS ≥ 6 on day of life 30 is associated with higher mortality and longer period of mechanical ventilation in premature infants requiring mechanical ventilation through 30 days of life.
BackgroundAlmost one million prematurely born infants die annually from respiratory insufficiency, predominantly in countries with limited access to respiratory support for neonates. The primary hypothesis tested in the present study was that a modified device for bubble nasal continuous positive airway pressure (Bn-CPAP) would provide lower work of spontaneous breathing, estimated by esophageal pressure-rate products.MethodsInfants born <32 weeks gestation and stable on Bn-CPAP with FiO2 <0.30 were studied within 72 h following delivery. Esophageal pressures during spontaneous breathing were measured during 2 h on standard Bn-CPAP, then 2 h with Bn-CPAP using a modified bubble device presently termed Seattle-PAP, which produces a different pattern of pressure fluctuations and which provided greater respiratory support in preclinical studies, then 2 h on standard Bn-CPAP.ResultsAll 40 infants enrolled completed the study and follow-up through 36 wks post menstrual age or hospital discharge, whichever came first. No infants were on supplemental oxygen at completion of follow-up. No infants developed pneumothoraces or nasal trauma, and no adverse events attributed to the study were observed. Pressure-rate products on the two devices were not different, but effort of breathing, assessed by areas under esophageal pressure-time curves, was lower with Seattle-PAP than with standard Bn-CPAP.ConclusionUse of Seattle-PAP to implement Bn-CPAP lowers the effort of breathing exerted even by relatively healthy spontaneously breathing premature neonates. Whether the lower effort of breathing observed with Seattle-PAP translates to improvements in neonatal mortality or morbidity will need to be determined by studies in appropriate patient populations.
Objective Congenital lower urinary tract obstruction (LUTO) is a rare condition with high perinatal mortality and morbidity when associated with severe oligohydramnios or anhydramnios in the second trimester of pregnancy. Severe pulmonary hypoplasia and end‐stage renal disease are the underlying causes of poor neonatal outcome in these cases. However, little is known about the subset of fetal LUTO that is associated with a normal volume of amniotic fluid at midgestation. The objective of the current study was to describe the natural history, underlying causes, survival and postnatal renal function outcomes in pregnancies with fetal LUTO and normal amniotic fluid volume during the second trimester of pregnancy. Methods This was a retrospective study of all pregnancies with fetal LUTO and normal amniotic fluid volume in the second trimester that received prenatal and postnatal care at our quaternary care institution between 2013 and 2017. Data on demographic characteristics, fetal interventions, perinatal survival, need for neonatal respiratory support, postnatal renal function and need for dialysis at the age of 1 and 24 months were analyzed. Results Of the 18 fetuses that met the study criteria, 17 (94.4%) survived the perinatal period. Eleven (61.1%) pregnancies developed oligohydramnios in the third trimester, six of which were eligible for and underwent fetal intervention with vesicoamniotic shunt placement, which was performed successfully in all six cases. Two (11.1%) neonates required respiratory support owing to pulmonary hypoplasia. At the age of 2 years, 14 children had follow‐up information available, two (14.3%) of whom had normal renal function, eight (57.1%) had developed some degree of chronic kidney disease (Stage 1–4) and four (28.6%) had developed end‐stage renal disease (ESRD), including two who had already manifested ESRD in the neonatal period. Conclusions Most fetuses diagnosed prenatally with LUTO that is associated with a normal volume of amniotic fluid at midgestation will have a favorable outcome in terms of perinatal survival and few will need long‐term respiratory support. However, these children are still at increased risk for chronic renal disease, ESRD and need for renal replacement therapy. Larger multicenter studies are needed to characterize the prenatal factors associated with postnatal renal function, and to investigate the role of fetal intervention in the group of fetuses that present with late‐onset oligohydramnios and evidence of preserved fetal renal function. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.