This research measured the concentration levels of radon in groundwater and determined the ingestion and inhalation dose. The study used RAD7 detector with RAD7-H2O accessory from Durridge Company to determine the radon levels. Thirty water samples in granitic dominated regions were collected from various areas of Bungoma County: ten from boreholes (BH), ten from hand dug wells (WL) and ten from springs (SP). The water samples were collected in 250 ml bottles which were tightly covered with lid to avoid radon leakage. The highest value was 303±4.00 KBq/m3 recorded in Kanduyi well and the lowest was 126±11.4kBq/m3 from where most of the samples recorded a high radon concentration with a mean of 269±5.25 KBq/m3 in wells, 213±7.96 KBq/m3 in boreholes and 290±7.70 KBq/m3 in springs. The average ingestion dose was found to be 1.5±0.07mSv/yr, 1.9±0.09 mSv/yr and 2.1±0.1 mSv/yr. The average annual effective dose rate for the samples collected were 2±0.1 mSv/yr for boreholes, 2.6±0.13 mSv/yr for wells and 2.7±0.14 mSv/yr for springs. The samples reported an average value of AED higher than the world average of 1.15 mSv/yr but below the exception limit of recommended action level of 10 mSv/yr hence the radon concentration levels in underground water in the study area has minimal health implications to the population.
This research measured the concentration levels of radon in groundwater and determined the ingestion and inhalation dose. The study used RAD7 detector with RAD7-H2O accessory from Durridge Company to determine the radon levels. Thirty water samples in granitic dominated regions were collected from various areas of Bungoma County: ten from boreholes (BH), ten from hand dug wells (WL) and ten from springs (SP). The water samples were collected in 250 ml bottles which were tightly covered with lid to avoid radon leakage. The highest value was 303±4.00 KBq/m 3 recorded in Kanduyi well and the lowest was 126±11.4kBq/m 3 from where most of the samples recorded a high radon concentration with a mean of 269±5.25 KBq/m 3 in wells, 213±7.96 KBq/m 3 in boreholes and 290±7.70 KBq/m 3 in springs. The average ingestion dose was found to be 1.5±0.07mSv/yr, 1.9±0.09 mSv/yr and 2.1±0.1 mSv/yr. The average annual effective dose rate for the samples collected were 2±0.1 mSv/yr for boreholes, 2.6±0.13 mSv/yr for wells and 2.7±0.14 mSv/yr for springs. The samples reported an average.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.