Background In hot weather, electric fans can potentially provide effective cooling for people, with lower greenhouse gas emissions and cost than air conditioning. However, international public health organisations regularly discourage fan use in temperatures higher than 35°C, despite little evidence. We aimed to determine humidity-dependent temperature thresholds at which electric fans would become detrimental in different age groups.Methods We used biophysical modelling to determine the upper humidity-dependent temperature thresholds at which fan use would become detrimental (ie, worsen heat stress) for healthy young adults (aged 18-40 years), healthy older adults (aged ≥65 years), and older adults taking anticholinergic medication. We also obtained hourly environmental data for the period Jan 1, 2007, to Dec 31, 2019, for 108 populous cities to determine the number of days fan use would be effective for cooling, standardised to a 31-day hot weather month. We established simplified temperature thresholds for future fan use recommendations on the basis of temperatures below which fan use would never have been detrimental between Jan 1, 2007, and Dec 31, 2019, across all prevailing levels of ambient humidity. FindingsAccording to our model, fan use would have been beneficial on 30•0 (96•6%) of 31 hot weather days for healthy young adults and 29•4 (94•9%) of 31 hot weather days for both older adults and older adults taking anticholinergic medication between Jan 1, 2007, and Dec 31, 2019. Adherence to the current WHO recommendation of fan use below temperatures of 35°C only, fan use would have been recommended on 27•2 days (87•7%) of 31 hot weather days. According to our simplified thresholds for fan use (at temperatures <39•0°C for healthy young adults, <38•0°C for healthy older adults, and <37•0°C for older adults taking anticholinergic medication), fan use would have been recommended on 29•6 (95•5%) of 31 hot weather days in healthy young adults, 29•4 (94•8%) days in healthy older adults, and 28•8 (93•0%) days in older adults taking anticholinergic medication between Jan 1, 2007, and Dec 31, 2019. Interpretation Electric fan use, particularly for healthy young adults, would not have worsened heat stress on the majority of study days between 2007 and 2019. Our newly proposed thresholds for fan use provide simple guidelines that improve future heatwave fan use recommendations.
We sought to determine 1) the influence of adiposity on thermoregulatory responses independently of the confounding biophysical factors of body mass and metabolic heat production (Hprod); and 2) whether differences in adiposity should be accounted for by prescribing an exercise intensity eliciting a fixed Hprod per kilogram of lean body mass (LBM). Nine low (LO-BF) and nine high (HI-BF) body fat males matched in pairs for total body mass (TBM; LO-BF: 88.7 ± 8.4 kg, HI-BF: 90.1 ± 7.9 kg; P = 0.72), but with distinctly different percentage body fat (%BF; LO-BF: 10.8 ± 3.6%; HI-BF: 32.0 ± 5.6%; P < 0.001), cycled for 60 min at 28.1 ± 0.2 °C, 26 ± 8% relative humidity (RH), at a target Hprod of 1) 550 W (FHP trial) and 2) 7.5 W/kg LBM (LBM trial). Changes in rectal temperature (ΔTre) and local sweat rate (LSR) were measured continuously while whole body sweat loss (WBSL) and net heat loss (Hloss) were estimated over 60 min. In the FHP trial, ΔTre (LO-BF: 0.66 ± 0.21 °C, HI-BF: 0.87 ± 0.18 °C; P = 0.02) was greater in HI-BF, whereas mean LSR (LO-BF 0.52 ± 0.19, HI-BF 0.43 ± 0.15 mg·cm(-2)·min(-1); P = 0.19), WBSL (LO-BF 586 ± 82 ml, HI-BF 559 ± 75 ml; P = 0.47) and Hloss (LO-BF 1,867 ± 208 kJ, HI-BF 1,826 ± 224 kJ; P = 0.69) were all similar. In the LBM trial, ΔTre (LO-BF 0.82 ± 0.18 °C, HI-BF 0.54 ± 0.19 °C; P < 0.001), mean LSR (LO-BF 0.59 ± 0.20, HI-BF 0.38 ± 0.12 mg·cm(-2)·min(-1); P = 0.04), WBSL (LO-BF 580 ± 106 ml, HI-BF 381 ± 68 ml; P < 0.001), and Hloss (LO-BF 1,884 ± 277 kJ, HI-BF 1,341 ± 184 kJ; P < 0.001) were all greater at end-exercise in LO-BF. In conclusion, high %BF individuals demonstrate a greater ΔTre independently of differences in mass and Hprod, possibly due to a lower mean specific heat capacity or impaired sudomotor control. However, thermoregulatory responses of groups with different adiposity levels should not be compared using a fixed Hprod in watts per kilogram lean body mass.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.