BackgroundThe number of patients with congenital heart disease (CHD) is increasing worldwide and most of them will require cardiac surgery, once or more, during their lifetime. The total volume of cardiac surgery in CHD patients at a national level and the associated mortality and predictors of death associated with surgery are not known. We aimed to investigate the surgical volume and associated mortality in CHD patients in England.MethodsUsing a national hospital episode statistics database, we identified all CHD patients undergoing cardiac surgery in England between 1997 and 2015.ResultsWe evaluated 57,293 patients (median age 11.9years, 46.7% being adult, 56.7% female). There was a linear increase in the number of operations performed per year from 1,717 in 1997 to 5,299 performed in 2014. The most common intervention at the last surgical event was an aortic valve procedure (9,276; 16.2%), followed by repair of atrial septal defect (9,154; 16.0%), ventricular septal defect (7,746; 13.5%), tetralogy of Fallot (3,523; 6.1%) and atrioventricular septal defect (3,330; 5.8%) repair. Associated mortality remained raised up to six months following cardiac surgery. Several parameters were predictive of post-operative mortality, including age, complexity of surgery, need for emergency surgery and socioeconomic status. The relationship of age with mortality was “U”-shaped, and mortality was highest amongst youngest children and adults above 60 years of age.ConclusionsThe number of cardiac operations performed in CHD patients in England has been increasing, particularly in adults. Mortality remains raised up to 6-months after surgery and was highest amongst young children and seniors.
Mitral regurgitation is a common valvular disorder. Transcatheter edge-to-edge repair (TEER) is a minimally invasive technique which involves holding together the middle segments of the mitral valve leaflets, thereby reducing regurgitation. To date, MitraClip™ is the only Food and Drug Administration (FDA)-approved device for TEER. The MitraClip procedure is technically challenging, characterised by a steep learning curve. Training is generally performed on simplified models, which do not emphasise anatomical features, realistic materials, or procedural scenarios. The aim of this study is to propose a novel, 3D printed simulator, with a major focus on reproducing the anatomy and plasticity of all areas of the heart involved and specifically the ones of the mitral valve apparatus. A three-dimensional digital model of a heart was generated by segmenting computed tomography (CT). The model was subsequently modified for: (i) adding anatomical features not fully visible with CT; (ii) adapting the model to interact with the MitraClip procedural equipment; and (iii) ensuring modularity of the system. The model was manufactured with a Polyjet technology printer, with a differentiated material assignment among its portions. Polypropylene threads were stitched to replicate chordae tendineae. The proposed system was successfully tested with MitraClip equipment. The simulator was assessed to be feasible to practice in a realistic fashion, different procedural aspects including access, navigation, catheter steering, and leaflets grasping. In addition, the model was found to be compatible with clinical procedural imaging fluoroscopy equipment. Future studies will assess the effect of the proposed training system on improving TEER training.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.