This study was conducted to optimize the cone beam computed tomography image quality in implant dentistry using both clinical and quantitative image quality evaluation with measurement of the radiation dose. A natural bone human skull phantom and an image quality phantom were used to evaluate the images produced after changing the exposure parameters (kVp and mA). A 10 × 5 cm2 field of view was selected for average adult. Five scans were taken with varying kVp (70–90 kVp) first at fixed 4 mA. After assessment of the scans and selecting the best kVp, nine scans were taken with 2–12 mA, and the kVp was fixed at the optimal value. A clinical assessment of the implant‐related anatomical landmarks was done in random order by two blinded examiners. Quantitative image quality was assessed for noise/uniformity, artifact added value, contrast‐to‐noise ratio, spatial resolution, and geometrical distortion. A dosimetry index phantom and thimble ion chamber were used to measure the absorbed dose for each scan setting. The anatomical landmarks of the maxilla had good image quality at all kVp settings. To produce good quality images, the mandibular landmarks demanded higher exposure parameters than the maxillary landmarks. The quantitative image quality values were acceptable at all selected exposure settings. Changing the exposure parameters does not necessarily produce higher image quality outcomes but does affect the radiation dose to the patient. The image quality could be optimized for implant treatment planning at lower exposure settings and dose than the default settings.
Objectives: Decontamination of biofilm-colonized rough implant surfaces remains challenging. We investigated the effect of airflow with glycine powder (AFG) on decontamination of mature oral multispecies biofilm from a sandblasted and acid etched (SLA) titanium surface.Materials and Methods: Subgingival dental plaque was cultured on SLA disks anaerobically for 21 days. AFG with various settings and distances was applied directly on the disks with or without previous rinse of 0.9% NaCl. The specimens were then analyzed through scanning electron microscope and remaining bacteria on the implant surface were quantified and statistically compared.Results: Mature oral biofilm with cocci and rods as major morphotypes, as well as spiral-and filamentous-shaped organisms, was formed on the untreated disks. Saline rinsing removed the thick biofilm layer but left numerous of coccoid bacteria in rough surface pits. AFG effectively removed most of the bacteria from the pits. Both 25% and 50% power settings were equally effective at 3-mm distance. With 50% power, AFG successfully removed bacteria at both 3-and 6-mm distance. When AFG was applied on native biofilm without prior rinsing with saline, it effectively removed the biofilm including bacteria in the pits. Conclusion:Application of AFG appears effective in removing bacteria from rough implant surfaces.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.