Rapid detection of viral contamination remains a pressing issue in various fields related to human health including clinical diagnostics, the monitoring of food-borne pathogens, the detection of biological warfare agents as well as in viral clearance studies for biopharmaceutical products. The majority of currently available assays for virus detection are expensive, time-consuming, and labor-intensive. In the present work we report the creation of a novel micro total analysis system (microTAS) capable of continuously monitoring viral contamination with high sensitivity and selectivity. The specific interaction between shape and surface chemistry between molecular imprinted polymer (MIP) and virus resulted in the elimination of non-specific interaction in the present sensor configuration. The additional integration of the blank (non-imprinted) polymer further allowed for the identification of non-specific adsorption events. The novel combination of microfluidics containing integrated native polymer and MIP with contact-less dielectric microsensors is evaluated using the Tobacco Mosaic Virus (TMV) and the Human Rhinovirus serotype 2 (HRV2). Results show that viral binding and dissociation events can be readily detected using contact-less bioimpedance spectroscopy optimized for specific frequencies. In the present study optimum sensor performance was achieved at 203 kHz within the applied frequency range of 5-500 kHz. Complete removal of the virus from the MIP and device reusability is successfully demonstrated following a 50-fold increase in fluid velocity. Evaluation of the microfluidic biochip revealed that microchip technology is ideally suited to detect a broader range of viral contaminations with high sensitivity by selectively adjusting microfluidic conditions, sensor geometries and choice of MIP polymeric material.
An under recognized cause of preventable mortality is healthcare-associated (nosocomial) infections such as biofilms found on implants and catheters. About 5% of U.S. and E.U. patients acquire nosocomial infections leading to prolonged hospitalization, increased patient suffering, and mortality rates. To date, no satisfactory solutions are available to monitor biofilm formation under near-native conditions. As a consequence, in the present work, we report the development of a disposable microfluidic biochip capable of continuously monitoring cell population dynamics under physiological shear force conditions. We demonstrate the simultaneous application of contactless bioimpedance spectroscopy and amperometric measurements to monitor fungal biofilm growth rates and metabolic activities. Quantitative cell analysis is accomplished by the use of high-density interdigitated capacitors (microIDC) isolated by a 700 nm epoxy (SU-8 resist) based passivation layer to noninvasively assess biofilm formation in predefined proliferation chambers. Additionally, biofilm respiration activity is measured using redox-mediators oxidized at band electrodes located downstream within microchannels. The disposable biofilm analysis platform is used to continuously monitor the dynamic responses of C. albicans to different glucose and galactose concentrations.
Although liposomes have many outstanding features such as biocompatibility, biodegradability, low toxicity and structural diversity, and are successfully applied in many areas of chemistry and biotechnology, a lack of characterization standards and quality control tools are still inhibiting the translation of liposome technology into clinical routine. The greatest obstacle to clinical scale commercialization is the inability to ensure liposome formulation stability because small size variations or altered surface chemistries can significantly influence in vivo distribution and excretion kinetics that could in turn lead to unpredictable therapy outcomes. To enhance the product development process we have developed a microfluidic biochip containing embedded dielectric microsensors capable of providing quantitative results on formulation composition and stability based on the monitoring of the unique electric properties of liposomes. Computational fluid dynamic (CFD) simulations confirmed that microfluidics offer reproducible and well-defined measurement conditions where a moving liposome suspension within a microchannel behaves like a bulk material. Results of this study demonstrate the ability of microfluidics, in combination with dielectric spectroscopy and multivariate data analysis methods, to identify nine different liposomes. We also show that various liposome modifications such as membrane-bound surface proteins, lipid bilayer soluble drugs, as well as protein and dye encapsulations, can be detected in the absence of any labels or indicators. Since shelf-life stability of a liposome formulation is regarded of prime importance for regulatory approval and clinical application, we further provide a possible practical application of the developed liposome analysis platform as a high-throughput tool for industrial quality insurance purposes.
Interdigital electrode structures (IDES) play a major role in many technical and analytical applications. In particular, they are a key technology in modern lab-on-a-chip (LOC) devices. As high sensitivity is a key component of any (bio)analytical method, the presented work is aimed at designing a novel dielectric sensing system, which exhibits maximum sensor sensitivity using passivated dielectric microsensors. Although the implementation of high-ε(r) dielectric passivation materials such as tantalum oxide or titanium oxide showed increased sensor sensitivity by a factor of 5, simulations revealed that sensor sensitivity is ultimately determined by the dielectric properties of the analyte. Ideally, dielectric properties of the passivation material need to be adjusted to the dielectric properties of the material under investigation and any deviations (e.g. higher or lower dielectric constants) will result in significant loss of sensitivity. To address these shortcomings we have developed a novel dielectric sensing concept based on a dual-material passivation geometry. The novel design consists of electric flux barriers that are layered between the finger electrodes, as well as electric flux guides which are located above the electrode structures that direct the entire generated electric flux to the object under investigation. Our 3D numerical results clearly show that the novel design offers two main advantages: firstly, the measurement sensitivity is further increased by more than a factor of two in comparison to a homogeneous passivation material sensing strategy. Secondly, maximum sensitivity for a given set of finger geometries can be achieved using a single sensor design regardless of the frequency-dependent dielectric properties of the measured objects. Hence, the novel approach is capable of reducing design and manufacturing costs of lab-on-a-chip devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.