Determination of elemental concentrations in biological tissue is fundamental to many environmental studies. Analytical methods typically used to quantify concentrations in such studies have minimum sample volumes that necessitate lethal or impactful collection of tissues. Laser-ablation inductively coupled mass spectrometry (LA-ICP-MS) has small sample-volume requirements and offers environmental practitioners an opportunity to employ low-impact sample-collection methods. Environmental applications of LA-ICP-MS are limited by the lack of validated methods, partly due to the need for dry samples and scarcity of matrix-matched certified reference materials (CRMs). This study validates an LA-ICP-MS method to determine concentrations of 30 elements in soft biological tissue (fish ovary and muscle). Small tissue samples (median: 0.48 grams (g); inter-quartile range: 0.30 g to 0.56 g wet weight) were dehydrated, powdered, compressed into pellets (weighing approximately 0.03 mg) and analysed using LA-ICP-MS alongside three matrix-matched CRMs. The method yielded concentration determinations for CRM elements that were typically accurate to within 30% of theoretical concentrations, and precise (relative standard deviation [RSD] <20%). These results were repeatable: accuracy rarely deviated from theoretical values by more than 20%, and precision rarely exceeded 33%. Determinations for biological samples were replicable irrespective of tissue (ovary or muscle). There was good linearity between analyte signal strength and theoretical concentration (median R2 ⥠0.981 for all elements) across ranges typically encountered in environmental studies. Concentrations could not be consistently obtained (i.e., determined concentrations were typically below detection limits) for boron, vanadium, molybdenum, and cadmium in muscles, and arsenic in both ovaries and muscles; however, detection limits were sufficiently low for most environmental contexts. Further methodological refinement could include the incorporation of spiked standards to extend linear ranges, and fine-tuning instrument parameters to obtain smoother signal intensities for rare elements. The method presented promotes the use low-impact sample-collection methods while enabling high-quality determinations of elemental concentrations in biological tissues.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.