Oxygen free radicals (OFRs) are associated with ischaemia-reperfusion injury involving many organs, including the heart, which can lead to depressed cardiac function and abnormalities in the cardiac ultrastructure. This is seen upon the release of the aortic crossclamp when the ischaemic myocardium is reperfused in patients undergoing cardiopulmonary bypass (CPB). Various studies have shown that by adding OFR scavenging agents or antioxidants to the CPB prime or cardioplegia, cardiac performance improves. Mannitol is an osmotic diuretic with free radical scavenging properties, which has been shown to reduce the extent of ischaemic injury and improve the function of the myocardium. This study evaluated how effective mannitol is as an OFR scavenger by administering different concentrations of cardioplegia antegrade into the aortic root, thus maximising its effects directly upon the myocardium rather than being diluted in the CPB prime. Thirty-three patients undergoing primary coronary artery bypass grafting (CABG) were, by double blind random selection, allocated into one of three groups: group 1, a control group (consisting of 11 patients) receiving no mannitol; group 2 (11 patients), receiving a concentration of 4 g/l; and group 3 (11 patients), receiving 8 g/l. Three blood samples were taken directly from the coronary sinus during bypass: the first sample at the start of bypass, just prior to the crossclamp being applied; the second sample just after removal of the crossclamp; and the third sample just prior to termination of bypass. All samples were then centrifuged and the plasma analysed for malondialdehyde (MDA) using high-performance liquid chromatography (HPLC). MDA, an endproduct of lipid peroxidation, causes cellular damage and disruption of cell membranes when tissue antioxidants are exhausted. The more MDA produced, the greater the depletion of tissue antioxidants secondary to OR formation during reperfusion when the aortic crossclamp is removed. HPLC is a useful biochemical study; however, it is not a direct indicator of depressed myocardial function, such as an invasive test would be, and this should be borne in mind. Statistically, the results do not show a significant difference among the three groups or among the three samples. However, a trend can be seen, which shows lower levels of MDA in the two groups receiving mannitol and there is an indication of a rise in MDA levels upon the start of reperfusion in the two groups receiving mannitol, but not the control group. It is concluded that further samples would be needed to find a significant difference in MDA concentrations.
Despite aiming for the same target pump flow, periodic limitations of venous return to the pump resulted in a significant reduction in average flow delivered to the patient by Mini-CPB. Less haemodilution compensated for this reduction, so that the average oxygen delivery was the same. The association between oxygen delivery and postoperative change in plasma creatinine was evident in both groups. Further work to understand whether there is a particular cohort of patients who benefit (or are put at risk) by one method of CPB vs the other is warranted.
2Blood Bank, Leeds Teaching Hospitals NHS Trust, Leeds, UK This case showed that it is possible for haemoglobin released by haemolysis in the extracorporeal circuit to pass through a high permeability (albumin retaining) dialyser membrane. In the incident described, the blood leak detector of the dialysis machine was activated before the patient became symptomatic. Haemolysis should be considered as a possible cause of blood leak alarms during dialysis with high flux membranes
The average indexed bypass pump flow was significantly lower with Mini-CPB. When combined with haemoglobin concentration, the average oxygen delivery was the same between groups. Patients in the C-CPB group had a greater duration and severity of cerebral desaturation to a level <20% below baseline values, but none reached the depth and duration of the cerebral desaturation associated with poor outcome. Cerebral oxygen desaturation with C-CPB was significantly associated with low flows during bypass, whereas desaturation with Mini-CPB was associated with low perioperative haemoglobin concentration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.