ObjectivesTo determine the validity of the Manchester Triage System (MTS) in emergency care for the general population of patients attending the emergency department, for children and elderly, and for commonly used MTS flowcharts and discriminators across three different emergency care settings.MethodsThis was a prospective observational study in three European emergency departments. All consecutive patients attending the emergency department during a 1-year study period (2010–2012) were included. Validity of the MTS was assessed by comparing MTS urgency as determined by triage nurses with patient urgency according to a predefined 3-category reference standard as proxy for true patient urgency.Results288,663 patients were included in the analysis. Sensitivity of the MTS in the three hospitals ranged from 0.47 (95%CI 0.44–0.49) to 0.87 (95%CI 0.85–0.90), and specificity from 0.84 (95%CI 0.84–0.84) to 0.94 (95%CI 0.94–0.94) for the triage of adult patients. In children, sensitivity ranged from 0.65 (95%CI 0.61–0.70) to 0.83 (95%CI 0.79–0.87), and specificity from 0.83 (95%CI 0.82–0.83) to 0.89 (95%CI 0.88–0.90). The diagnostic odds ratio ranged from 13.5 (95%CI 12.1–15.0) to 35.3 (95%CI 28.4–43.9) in adults and from 9.8 (95%CI 6.7–14.5) to 23.8 (95%CI 17.7–32.0) in children, and was lowest in the youngest patients in 2 out of 3 settings and in the oldest patients in all settings. Performance varied considerably between the different emergency departments.ConclusionsValidity of the MTS in emergency care is moderate to good, with lowest performance in the young and elderly patients. Future studies on the validity of triage systems should be restricted to large, multicenter studies to define modifications and improve generalizability of the findings.
Background: Following internal fixation of intertrochanteric hip fractures, tip apex distance, fracture classification, position ofthe screw in the femoral head, and fracture reduction are known predictors for screw cutout, but the reliability of these measurements is unknown. We investigated the reliability ofthe tip apex distance measurement, the Cleveland femoral head dividing system, the three-grade classification system of Baumgaertner for fracture reduction, and the AO classification system as predictors for screw cutout.
Summary Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79). Interpretation In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws. Funding National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
The clavicle hook plate is a suitable implant for Neer type II clavicle fractures. The advantage of this osteosynthesis is the possibility of immediate functional aftercare. We observed a high percentage of discomfort due to the implant; therefore, we advise to remove the implant as soon as consolidation has taken place.
Background The primary aim of the present study was to verify the potential risk factors for developing a delirium after hip fracture surgery. The secondary aim of this study was to examine the related clinical outcomes after a delirium developed post-hip fracture surgery. Patients and methods Data were extracted from a prospective hip fracture database and completed by retrospective review of the hospital records. A total of 463 patients undergoing hip fracture (hip hemiarthroplasty) surgery in a level II trauma teaching hospital between January 2011 and May 2016 were included. Delirium was measured using the Delirium Observation Screening Scale, the confusion assessment method, and an observatory judgment by geriatric medicine specialists. Results The results showed that 26% of the patients (n=121) developed a delirium during hospital stay with a median duration during admission of 5 days (IQR 3–7). The multivariable model showed that the development of delirium was significantly explained by dementia (OR 2.75, P =0.001), age (OR 1.06, P =0.005), and an infection during admission (pneumonia, deep surgical site infection, or urinary tract infection) (OR 1.23, P =0.046). After 1 year of follow-up, patients who developed delirium after hip fracture surgery were significantly more discharged to (semi-independent) nursing homes ( P <0.001) and had a significantly higher mortality rate ( P <0.001) compared to patients without delirium after hip fracture surgery. Conclusions The results showed that 26% of the patients undergoing hip fracture surgery developed a delirium. The risk factors including age, dementia, and infection during admission significantly predicted the development of the delirium. No association was confirmed between delirium and time of admission or time to surgery. The development of delirium after hip fracture surgery was subsequently found to be a significant predictor of admission to a nursing home and mortality after 1 year.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.