Two new HPTLC methods for quantification of isopropyl-9H-thioxanthen-9-one (ITX) in milk, yoghurt and fat samples have been developed. Extraction of ITX from milk and yoghurt was performed with a mixture of cyclohexane and ethyl acetate by employment of accelerated solvent extraction (ASE). For soy bean oil and margarine, a simple partitioning of ITX into acetonitrile was used. ITX and 2,4-diethyl-9H-thioxanthen-9-one (DTX) used as internal standard have been separated on silica gel 60 HPTLC plates with a mixture of toluene and n-hexane (4:1, v/v) and on RP18 HPTLC plates with a mixture of acetonitrile and water (9:1, v/v). Development was performed anti-parallel from both plate sides leading to a throughput of 36 separations in 7 min. Fluorescence measurement at 254/>400 nm was used for quantification. Limits of detection (S/N of 3) have been established to be 64 pg for ITX and DTX on both types of HPTLC plates. In fatty matrix (spiked butter) LOD of ITX was determined to be 1 mug kg(-1). In the working range monitored (20-200 microg kg(-1)) polynomial regression of ITX showed a relative standard deviation (sdv) of +/-1.51 % (r = 0.99981). Starting with the limit of quantification the response was linear (sdv = +/-2.18 %, r = 0.99893). Regarding repeatability (n = 9) a coefficient of variation (CV) of 1.1 % was obtained for ITX at 32 ng on silica gel plates and of 2.9 % on reversed-phase plates. Repeatabilities (n = 4) of ITX determination at 20, 50 and 100 microg kg(-1) in milk, yoghurt, soybean oil and margarine showed CVs between +/-1.0 and 6.4 %. The results prove that modern planar chromatography is a rapid and cost-efficient alternative method to quantify ITX in milk-based or fatty matrices. Only positive results are confirmed by online ESI/MS in the SIM mode (LOQ 128 pg) and by DART/MS involving a minimal employment of the MS device, which is a further advantage of HPTLC. Overall mean recovery rates of ITX at 20 or 50 and 100 microg kg(-1) (n = 8) were 41 % for milk, 70 % for yoghurt, 6 % for margarine and 12 % for soy bean oil. However, with the internal standard correction recoveries were about 130 % for milk and yoghurt and 70 and 97 % for margarine and soy bean oil, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.