Physicians should be alert about the possibility of subacute thyroiditis (SAT) being induced by COVID‐19 vaccination. SAT may present with anterior neck pain, extended fever or palpitation in recently vaccinated patients, which should not be easily dismissed as expected post‐vaccination flu‐like symptoms, thereby, facilitating in time diagnosis and treatment.
Purpose:To compare macular thickness in children with functional amblyopia and those without amblyopia using optical coherence tomography (OCT).Methods:This case-control study was conducted on 93 children aged 3–10 years including 44 cases with unilateral amblyopia and 49 subjects without amblyopia. Amblyopic eyes were considered as the case group and their fellow eyes as internal controls; eyes of non-amblyopic children served as the external control. Macular thickness of all eyes were measured by optical coherence tomography in the center (foveola), 1 mm ring (fovea), and 3 and 6 mm rings and compared.Results:Although macular thickness was generally not different between the study groups, there was a significant difference in central macular thickness between eyes with moderate to severe amblyopia and the external controls (P = 0.037). Foveal thickness difference exceeding 10 microns between fellow eyes was detected in a larger number of amblyopic children as compared to non-amblyopic controls (P = 0.002). Mean foveal thickness was greater in boys (P = 0.037) but there was no significant difference in foveal thickness among various types of refractive errors.Conclusion:Although there was no significant relationship between macular thickness and amblyopia, foveolar thickness in eyes with moderate to severe amblyopia was significantly greater than the external controls. Further studies with more cases of moderate to severe amblyopia are recommended.
Purpose:To determine the prevalence of color vision deficiency (CVD) and its correlation with amblyopia and refractive errors among primary school children.Methods:In this population-based cross-sectional study, 2160 children were selected from 36 primary schools; 60 students were from each school (10 students in each grade), with equal sex distribution. A complete eye examination including refraction using a photorefractometer, determination of visual acuity (VA) and color vision using a Yang vision tester, and evaluation of ocular media opacity using a direct ophthalmoscope was performed. Children who could not answer at least 4 plates of the Ishihara color test were considered as color vision deficient subjects. Amblyopia was determined if pinhole VA was worse than 0.3 LogMAR (equal to 20/40).Results:The prevalence of CVD was 2.2% (95% CI: 1.5% to 3%) which was higher in male subjects (37 [3.5%] boys vs. 11 [1.0%] girls, P < 0.001). Mean VA was lower among students with CVD as compared to normal color vision children (P = 0.035) and amblyopia was observed in 8.3% (95% CI: 0.2% to 16.4%) of patients with CVD versus 2.1% (95% CI: 1.5% to 2.08%) of children with normal color vision perception (P = 0.005). A statistically significant correlation between lower VA and CVD was observed (P = 0.023).Conclusion:Although CVD was correlated with lower VA and amblyopia, there was no relationship between CVD and the type of amblyopia, refractive error, anisometropia or strabismus.
Purpose:To determine the accuracy of photorefraction and autorefraction as compared to cycloautorefraction and to detect the repeatability of photorefraction.Methods:This diagnostic study included the right eyes of 86 children aged 7-12 years. Refractive status was measured using photorefraction (PlusoptiX SO4, GmbH, Nürnberg, Germany) and autorefraction (Topcon RM800, USA) with and without cycloplegia. Photorefraction for each eye was performed three times to assess repeatability.Results:The overall agreement between photorefraction and cycloautorefraction was over 81% for all refractive errors. Photorefractometry had acceptable sensitivity and specificity for myopia and astigmatism. There was no statistically significant difference considering myopia and astigmatism in all comparisons, while the difference was significant for hyperopia using both amblyogenic (P = 0.006) and nonamblyogenic criteria (P = 0.001). A myopic shift of 1.21 diopter (D) and 1.58 D occurred with photorefraction in nonamblyogenic and amblyogenic hyperopia, respectively. Using revised cut-off points of + 1.12 D and + 2.6 D instead of + 2.00 D and + 3.50 D improved the sensitivity of photorefractometry to 84.62% and 69.23%, respectively. The repeatability of photorefraction for measurement of myopia, astigmatism and hyperopia was acceptable (intra-cluster correlation [ICC]: 0.98, 0.94 and 0.77, respectively). Autorefraction results were significantly different from cycloautorefraction in hyperopia (P < 0.0001), but comparable in myopia and astigmatism. Also, noncycloglegic autorefraction results were similar to photorefraction in this study.Conclusion:Although photorefraction was accurate for measurement of myopia and astigmatism, its sensitivity for hyperopia was low which could be improved by considering revised cut-off points. Considering cut-off points, photorefraction can be used as a screening method.
A 68-year-old man with metastatic castration-resistant prostate cancer and widespread bone metastases as well as a history of kidney transplant, underwent 5 cycles of 177Lu–prostate-specific membrane antigen 617 therapies in our department. Being more cautious of the radiation burden imposed on the transplanted kidney, a lower average dose of 4 GBq per cycle was administered (instead of the more routine 6.0-7.4 GBq per cycle). However, excellent response was noted and serum creatinine level of 0.8 mg/dL remained stable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.