This work aims at determining the ability of a deep learning (DL) algorithm to measure retinal nerve fiber layer (RNFL) thickness from optical coherence tomography (OCT) scans in anterior ischemic optic neuropathy (NAION) and demyelinating optic neuritis (ON). The training/validation dataset included 750 RNFL OCT B-scans. Performance of our algorithm was evaluated on 194 OCT B-scans from 70 healthy eyes, 82 scans from 28 NAION eyes, and 84 scans of 29 ON eyes. Results were compared to manual segmentation as a ground-truth and to RNFL calculations from the built-in instrument software. The Dice coefficient for the test images was 0.87. The mean average RNFL thickness using our U-Net was not different from the manually segmented best estimate and OCT machine data in control and ON eyes. In NAION eyes, while the mean average RNFL thickness using our U-Net algorithm was not different from the manual segmented value, the OCT machine data were different from the manual segmented values. In NAION eyes, the MAE of the average RNFL thickness was 1.18 ± 0.69 μm and 6.65 ± 5.37 μm in the U-Net algorithm segmentation and the conventional OCT machine data, respectively (P = 0.0001).
This work aims at determining the ability of a deep learning (DL) algorithm to measure retinal nerve fiber layer (RNFL) thickness from optical coherence tomography (OCT) scans in anterior ischemic optic neuropathy (NAION) and demyelinating optic neuritis (ON). The training/validation dataset included 750 RNFL OCT B-scans. Performance of our algorithm was evaluated on 194 OCT B-scans from 70 healthy eyes, 82 scans from 28 NAION eyes, and 84 scans of 29 ON eyes. Results were compared to manual segmentation as a ground-truth and to RNFL calculations from the built-in instrument software. The Dice coefficient for the test images was 0.87. The mean average RNFL thickness using our U-Net was not different from the manually segmented best estimate and OCT machine data in control and ON eyes. In NAION eyes, while the mean average RNFL thickness using our U-Net algorithm was not different from the manual segmented value, the OCT machine data were different from the manual segmented values. In NAION eyes, the MAE of the average RNFL thickness was 1.18 ± 0.69 µm and 6.65 ± 5.37 µm in the U-Net algorithm segmentation and the conventional OCT machine data, respectively (P = 0.0001).
Purpose: In this study, an algorithm based on deep learning was presented to reduce the retinal nerve fiber layer (RNFL) segmentation errors in spectral domain optical coherence tomography (SD-OCT) scans using ophthalmologists’ manual segmentation as a reference standard. Methods: In this study, we developed an image segmentation network based on deep learning to automatically identify the RNFL thickness from B-scans obtained with SD-OCT. The scans were collected from Farabi Eye Hospital (500 B-scans were used for training, while 50 were used for testing). To remove the speckle noise from the images, preprocessing was applied before training, and postprocessing was performed to fill any discontinuities that might exist. Afterward, output masks were analyzed for their average thickness. Finally, the calculation of mean absolute error between predicted and ground truth RNFL thickness was performed. Results: Based on the testing database, SD-OCT segmentation had an average dice similarity coefficient of 0.91, and thickness estimation had a mean absolute error of 2.23 ± 2.1 μm. As compared to conventional OCT software algorithms, deep learning predictions were better correlated with the best available estimate during the test period (r2 = 0.99 vs r2 = 0.88, respectively; P < 0.001). Conclusion: Our experimental results demonstrate effective and precise segmentation of the RNFL layer with the coefficient of 0.91 and reliable thickness prediction with MAE 2.23 ± 2.1 μm in SD-OCT B-scans. Performance is comparable with human annotation of the RNFL layer and other algorithms according to the correlation coefficient of 0.99 and 0.88, respectively, while artifacts and errors are evident.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.