Based on the findings of this study, using orthoses with different mechanisms such as proprioceptive intervention might be a useful method in orthotic treatment. Assessing plantar pressure can also be an efficient quantitative outcome measure for clinicians in evidence-based foot orthosis prescription.
Background: Children with cerebral palsy (CP) often demonstrate postural control difficulties. Orthotic management may assist in improving postural control in these children. Objective: The purpose of this investigation was to examine the influence of floor reaction ankle foot orthosis (FRAFO) on postural flexion called the crouch position in children with CP. Study Design: Quasi-experimental. Methods: Eight children with spastic diplegic CP and eight matched typically developing children participated in this study. Postural control of children with CP was assessed in a static standing position on a force platform with/without a FRAFO. The parameters used were centre of pressure (CoP) measures, calculated from force platform signals including the standard deviation (SD) of excursion; phase plate portrait and SD of velocity in anteroposterior (AP) and mediolateral (ML) directions. Results: The maximum knee extension was statistically significant in children with CP when barefoot compared to wearing braced footwear (p < 0.05, t = 10.01). AP and ML displacement, AP velocity and AP phase plate portrait of CoP were not statistically significant between children with CP with/without a FRAFO (p < 0.05). Conclusion: FRAFO can improve the alignment of the knee, but may not be helpful in improving postural control in children with CP in a short time period.
Clinical relevanceThis article will provide objective evidence about the effect of FRAFO on the postural control in children with CP. Therapists can use FRAFO to effectively decrease the knee joint angle in the sagittal plane in children with spastic CP, but cannot use it to improve the postural control.
Background: The aim of this case study was to analyze the effect on gait parameters of a new design of powered gait orthosis which applied synchronized motions to both the hip and knee joints when utilized for walking by a spinal cord injury (SCI) patient.Case Description and Methods: Two orthoses were evaluated while worn by an incomplete SCI subject. Gait evaluation was performed when walking with an isocentric reciprocating gait orthosis (IRGO) and compared to that demonstrated by a newly developed powered version. This new orthosis was based on the IRGO superstructure but incorporated powered hip and knee joints using electrically motorized actuators.Findings and Outcomes: These gait parameters were improved when compared to standard IRGO and initial testing with the orthosis with only the hip or the knee joints activated in isolation. Maximum hip flexion and extension angles, as well as the maximum knee flexion and extension angles all increased when walking with the powered RGO compared to the IRGO.Conclusions: Gait evaluation of this newly developed orthosis showed improvement in measured parameters when compared to walking with an IRGO.Clinical relevanceThis case study gave the authors confidence to extend the research to a more extensive study with a group of SCI patients.
Background:The aim of this case study was to identify the effect of a powered hip orthosis on the kinematics and temporal-spatial parameters of walking by a patient with spinal cord injury (SCI). Case Description and Methods: Two orthoses were evaluated while worn by an incomplete SCI subject with a T-8level of injury. Gait evaluation was performed when walking with an Isocentric Reciprocating Gait Orthosis (IRGO) and compared to that demonstrated by a newly powered version of the orthosis; based on the IRGO superstructure but incorporating powered hip joints using an electrically motorized actuator that produced active hip joint extension and flexion. Findings and Outcomes: The powered hip orthosis, when compared to the IRGO, increased the speed of walking, the step length and also the cadence demonstrated by this subject. Vertical and horizontal compensatory motions with new orthosis decreased. Hip angles when walking with this orthosis were comparative to those demonstrated by normal walking patterns. Conclusions: The hip actuator produced positive effects on the kinematics and temporal-spatial parameters of gait during level-ground walking trials, resulting in an alternative approach to walking by SCI patients.
Clinical relevanceThis orthosis has the potential to improve hip joint kinematics, the temporal-spatial parameters of gait in SCI patients walking.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.