Introduction Traditionally, ciliary body destruction has been used to treat uncontrolled intraocular pressure (IOP) following maximally tolerable medical therapy. This is due to the large number of complications seen with this procedure. However, recently a new technique of sub-threshold laser or micropulse laser, is able to provide selective destruction of the ciliary body in a controlled manner. This avoids most of the complications seen with other modalities. We have performed a small case descriptive pilot study to assess the effectiveness of micropulse transscleral cyclophotocoagulation (MP-TSCPC) in lowering IOP. Methods This pilot study was conducted on four patients in the age range 55-70-years with intractable glaucoma. Two patients had primary angle closure glaucoma, one-each had steroid-induced glaucoma and neovascular glaucoma. Mean baseline IOP was 32±2.4 mmHg. Mean number of glaucoma medications were 2.5±1.5. All patients underwent 180° MP-TSCPC. Absolute success was defined as IOP<20 mmHg without acetazolamide. Results Following the procedure the patients were followed-up at days 1,7,30 and 90. At the last follow-up of the study, mean IOP was 18.2±1.2 mmHg in all four patients. Mild anterior chamber inflammation was the only complication noted. Mean number of glaucoma medications reduced to 1.5±1.0 following the procedure. Thus, absolute success was achieved in all patients. Conclusion This small pilot study validates other studies which show effectiveness of MP-TSCPC as an efficient and safe procedure to lower IOP. This procedure can be used over a wide variety of cases, though the indications for such procedures are still evolving. More extensive and long-term studies will clarify the position of this procedure in our glaucoma management practices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.