BACKGROUND To estimate the frequency and duration of detectable Zika virus (ZIKV) RNA in human body fluids, we prospectively assessed a cohort of newly infected participants in Puerto Rico. METHODS We evaluated samples obtained from 150 participants (including 55 men) in whom ZIKV RNA was detected on reverse-transcriptase–polymerase-chain-reaction (RT-PCR) assay in urine or blood in an enhanced arboviral clinical surveillance site. We collected serum, urine, saliva, semen, and vaginal secretions weekly for the first month and then at 2, 4, and 6 months. All specimens were tested by means of RT-PCR, and serum was tested with the use of anti–ZIKV IgM enzyme-linked immunosorbent assay. Among the participants with ZIKV RNA in any specimen at week 4, biweekly collection continued until all specimens tested negative. We used parametric Weibull regression models to estimate the time until the loss of ZIKV RNA detection in each body fluid and reported the findings in medians and 95th percentiles. RESULTS The medians and 95th percentiles for the time until the loss of ZIKV RNA detection were 14 days (95% confidence interval [CI], 11 to 17) and 54 days (95% CI, 43 to 64), respectively, in serum; 8 days (95% CI, 6 to 10) and 39 days (95% CI, 31 to 47) in urine; and 34 days (95% CI, 28 to 41) and 81 days (95% CI, 64 to 98) in semen. Few participants had detectable ZIKV RNA in saliva or vaginal secretions. CONCLUSIONS The prolonged time until ZIKV RNA clearance in serum in this study may have implications for the diagnosis and prevention of ZIKV infection. Current sexual-prevention guidelines recommend that men use condoms or abstain from sex for 6 months after ZIKV exposure; in 95% of the men in this study, ZIKV RNA was cleared from semen after about 3 months. (Funded by the Centers for Disease Control and Prevention.)
Dengue is an acute illness caused by the positive-strand RNA dengue virus (DENV). There are four genetically distinct DENVs (DENV-1–4) that cause disease in tropical and subtropical countries. Most patients are viremic when they present with symptoms; therefore, RT-PCR has been increasingly used in dengue diagnosis. The CDC DENV-1–4 RT-PCR Assay has been developed as an in-vitro diagnostic platform and was recently approved by the US Food and Drug Administration (FDA) for detection of dengue in patients with signs or symptoms of mild or severe dengue. The primers and probes of this test have been designed to detect currently circulating strains of DENV-1–4 from around the world at comparable sensitivity. In a retrospective study with 102 dengue cases confirmed by IgM anti-DENV seroconversion in the convalescent sample, the RT-PCR Assay detected DENV RNA in 98.04% of the paired acute samples. Using sequencing as a positive indicator, the RT-PCR Assay had a 97.92% positive agreement in 86 suspected dengue patients with a single acute serum sample. After extensive validations, the RT-PCR Assay performance was highly reproducible when evaluated across three independent testing sites, did not produce false positive results for etiologic agents of other febrile illnesses, and was not affected by pathological levels of potentially interfering biomolecules. These results indicate that the CDC DENV-1–4 RT-PCR Assay provides a reliable diagnostic platform capable for confirming dengue in suspected cases.
High rates of viremia were detected in blood donors in Puerto Rico coupled with the first documented transfusion transmission of severe dengue disease, suggesting that further research on interventions is needed.
The emergence and spread of Zika virus (ZIKV) presented a challenge to the diagnosis of ZIKV infections in areas with transmission of dengue (DENV) and chikungunya (CHIKV) viruses. To facilitate detection of ZIKV infections, and differentiate these infections from DENV and CHIKV, we developed the Trioplex real-time RT-PCR assay (Trioplex assay). Here, we describe the optimization of multiplex and singleplex formats of the assay for a variety of chemistries and instruments to facilitate global standardization and implementation. We evaluated the analytical performance of all Trioplex modalities for detection of these three pathogens in serum and whole blood, and for ZIKV in urine. The limit of detection for the three viruses and in different RNA-extraction modalities is near 103 genome copy equivalents per milliliter (GCE/mL). Simultaneous testing of more than one specimen type from each patient provides a 6.4% additional diagnostic sensitivity. Overall, the high sensitivity of the Trioplex assay demonstrates the utility of this assay ascertaining Zika cases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.