BackgroundThe aim of this study was to compare the streamlined liner of the pharynx airway (SLIPA), a new supraglottic airway device (SGA), with the laryngeal mask airway ProSeal™ (PLMA) during general anesthesia.MethodsSixty patients were randomly allocated to two groups; a PLMA group (n = 30) or a SLIPA group (n = 30). Ease of use, first insertion success rate, hemodynamic responses to insertion, ventilatory efficiency and positioning confirmed by fiberoptic bronchoscopy were assessed. Lung mechanics data were collected with side stream spirometry at 10 minutes after insertion. We also compared the incidence of blood stain, incidence and severity of postoperative sore throat and other complications.ResultsFirst attempt success rates were 93.3% and 73.3%, and mean insertion time was 7.3 sec and 10.5 sec in PLMA and SLIPA. There was a significant rise in all of hemodynamic response from the pre-insertion value at one minute following insertion of SLIPA. But, insertion of PLMA was no significant rise in hemodynamic response. There was no statistically significant difference in the mean maximum sealing pressure, gas leakage, lung mechanics data, gastric distension, postoperative sore throat and other complication between the two groups. Blood stain were noted on the surface of the device in 40% (n = 12) in the SLIPA vs. 6.7% (n = 2) in the PLMA.ConclusionsThe SLIPA is a useful alternative to the PLMA and have comparable efficacy and complication rates. If we acquire the skill to use, SLIPA may be considered as primary SGA devices during surgery under general anesthesia.
Purpose The aim of this study was to compare the Streamlined Liner of the Pharynx Airway (SLIPA TM ) with the ProSeal Laryngeal Mask Airway (LMA-ProSeal TM ) in mechanically ventilated paralyzed patients undergoing laparoscopic gynecologic surgery. Methods One hundred and one patients were allocated randomly to SLIPA (n = 50) or to LMA-ProSeal (n = 51) treatment groups. After induction of general anesthesia and insertion of the assigned supralaryngeal airway (SLA) device, we made note of the occurrence of any gastric insufflation and perilaryngeal leakage. We then evaluated the anatomical fit of the SLA device using a fibreoptic bronchoscope, and we assessed the airway sealing pressure and respiratory mechanics with change in head position and during peritoneal insufflation. After surgery, we evaluated the severity of postoperative sore throat and the presence of blood or regurgitated fluid on the SLA device. Results The insertion success rate, gastric insufflation, perilaryngeal leakage, anatomical fit, airway sealing pressure, respiratory mechanics, severity of sore throat, and incidence of blood and regurgitated fluid on the device were similar between the two groups. The incidence of perilaryngeal leakage with changes in the patient's head position was lower with the SLIPA group than with the LMA-ProSeal group (3/50 vs 11/51, respectively; P = 0.026). During peritoneal insufflation, perilaryngeal leakage did not occur with the SLIPA but occurred in four cases with the LMA-ProSeal (P = 0.045). Conclusion Both the SLIPA and the LMA-ProSeal can be used effectively and without severe complications in paralyzed patients undergoing laparoscopic gynecological surgery. However, the SLIPA offers the advantage of less perilaryngeal gas leakage than the LMA-ProSeal with change in head position and during insufflation of the peritoneal cavity. This trial is registered with ANZCTR (ACTRN12609000914268). RésuméObjectif L'objectif de cette e´tude e´tait de comparer le masque SLIPA TM (Streamlined Liner of the Pharynx Airway) et le masque LMA-ProSeal TM (ProSeal Laryngeal Mask Airway) chez des patientes curarise´es recevant une ventilation me´canique et subissant une chirurgie gyne´cologique par laparoscopie. Méthode Cent une patientes ont e´te´ale´atoirement re´parties en deux groupes de traitement, soit SLIPA (n = 50) et LMA-ProSeal (n = 51). Apre`s l'induction de l'anesthe´sie ge´ne´rale et l'insertion du masque supralaryngeá ttribue´, nous avons note´la survenue de toute insufflation gastrique ou fuite pe´rilarynge´e. Nous avons ensuite e´valueĺ 'ajustement anatomique du masque supralarynge´a`l'aide d'un bronchoscope a`fibres optiques, la pression de fermeture des voies ae´riennes et la me´canique respiratoire suite a`des changements de position de la teˆte et pendant l'insufflation pe´ritone´ale. Apre`s la chirurgie, nous avons e´value´la gravite´des maux de gorge postope´ratoires et la pre´sence de sang ou de liquides re´gurgite´s sur le masque supralarynge´.
Ischiofemoral impingement syndrome is an uncommon disorder defined by hip pain caused by the narrowing of the space between the ischial tuberosity and lesser trochanter with associated entrapment of the quadratus femoris muscle. We effectively treated two male patients using ultrasound-guided prolotherapy with polydeoxyribonucleotide sodium mixed with local anesthetics. A 24-year-old male patient with no history of trauma or surgery complained of bilateral hip and groin pain; magnetic resonance imaging demonstrated slight narrowing of the bilateral ischiofemoral spaces with mild enhancement of the left quadratus femoris muscle. A 23-year-old male patient with a history of iliotibial band release and iliopsoas tendon release complained of left hip and groin pain; magnetic resonance imaging revealed swelling of the left quadratus femoris muscle. After the fifth treatment session of prolotherapy, the pain severity score using the visual analog scale was found to be minimal (0-1/10), and follow-up magnetic resonance imaging revealed a slightly decreased enhancement of the quadratus femoris muscle compared with that on previous images. Prolotherapy with polydeoxyribonucleotide sodium was an efficacious treatment for two patients with ischiofemoral impingement syndrome who were not candidates for surgery.
BackgroundWe studied the differences in airway assessment factors among old, middle, and young age groups, and evaluated the frequency and causes of difficult intubation among these groups.MethodsPatients were divided into young (< 40 yr, n = 75 ), middle (40-59 yr, n = 83), and old (≥ 60 yr, n = 89) group. Airway assessment factors such as head and neck movement, thyromental distance, interincisor gap, dentition, Mallampati score, and Arné score were assessed. After muscle relaxation, cervical joint rigidity and Cormack-Lehane (C-L) grade were assessed. The differences in airway assessment factors between difficult (C-L grade 3, 4) and easy (C-L grade 1, 2) intubation were then examined. Logistic regression analysis was also carried out to identify the extent to which airway assessment factors reflected difficult intubation.ResultsAs aging, head and neck movement, thyromental distance, and interincisor gap decreased, the grade of dentition, Mallampati score, cervical joint rigidity and the ratio of Arné score > 11 increased. In the old and middle group, the incidence of difficult intubation was increased compared with the young group. Dentition in the young group, Mallampati score and interinsisor gap in the middle group and Mallampati score, cervical joint rigidity in the old group respectively predicted difficult intubation.ConclusionsCompared to young individuals, middle-aged or elderly adults are likely to experience more difficulty in endotracheal intubation and its predictive factors could vary by age group.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.