High energy internal cardioversion has been proposed as an alternative method to cardiovert drug refractory or external cardioversion refractory atrial fibrillation. However, the safety of this technique has not been clearly evaluated. We reviewed findings in 53 patients who underwent 55 sessions of high energy internal cardioversion (2 patients underwent 2 sessions) for termination of longstanding atrial fibrillation. Shocks energy varied from 70-270 J. Three patients had 3 shocks during the same session, 5 had 2, and 47 only 1. Success rate was 89% (success was defined as immediate conversion to normal sinus rhythm). Low cardiac output occurred in two patients, and resulted in the death of one of these individuals, a patient with significant hypertrophic cardiomyopathy and heart failure. The other patient recovered completely. In 11% of the cases, shock induced transient atrioventricular block, necessitating ventricular pacing until sinus rhythm was restored. In three patients, a moderate but asymptomatic and uncomplicated pericardial effusion was diagnosed on echocardiogram. Finally, four patients had side effects related to venous puncture, which resolved spontaneously. These results suggest that high energy internal cardioversion is effective for conversion of atrial fibrillation. However, the technique may not be optimal in patients with advanced hypertrophic cardiomyopathy and in such cases the technique should be used carefully and only in the case of failure of external cardioversion; no more than two shocks should be delivered during the same procedure. Temporary ventricular pacing should be provided in all patients and an echocardiogram should be performed before patients are being discharged.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.