All patients showed an improvement in quality of life and a reduction in handicap due to dizziness. Improvement in objective test results was also seen. These results were stable at follow-up. A correlation was found between different subjective measures, but there was no correlation between subjective and objective measures.
The electrical properties of the cytoplasmatic membrane of human erythrocyte cells have been evaluated by means of dielectric spectroscopy measurements in the radiowave frequency range, using the so-called "suspension method". Measurements have been carried out at different volume fractions of the corpuscular phase (the cell haematocrit) in order to investigate the influence of the cell-cell interactions on the electrical parameters (the membrane permittivity epsilon and the membrane conductivity sigma) of the cell membrane and a set of new values are proposed. Moreover, the influence of different alkali metal ions (Na+, K+, Cs+, Li+) on the ion permeation properties of the membrane are investigated and the structural alterations in the membrane organized briefly discussed.
The present paper concerns a new description of changing in metabolism during incremental exercises test that permit an individually tailored program of exercises for obese subjects. We analyzed heart rate variability from RR interval time series (tachogram) with an alternative approach, the recurrence quantification analysis, that allows a description of a time series in terms of its dynamic structure and is able to identify the phase transitions. A transition in cardiac signal dynamics was detected and it perfectly reflects the aerobic threshold, as identified by gas exchange during an incremental exercise test, revealing the coupling from the respiratory system toward the heart. Moreover, our analysis shows that, in the recurrence plot of RR interval, it is possible to identify a specific pattern that allows to identify phase transitions between different dynamic regimes. The perfect match of the occurrence of the phase transitions with changes observed in the VO 2 consumption, the gold standard approach to estimate thresholds, strongly supports the possibility of using our analysis of RR interval to detect metabolic threshold. In conclusion, we propose a novel nonlinear data analysis method that allows for an easy and personalized detection of thresholds both from professional and even from low-cost wearable devices, without the need of expensive gas analyzers.
Aims of this study were: to verify if Recurrence Quantification Analysis (RQA) of Heart Rate Variability (HRV) time series could determine both ventilatory thresholds in individuals with different fitness levels, and to assess the validity of RQA method compared to gas-exchange method (GE). The two thresholds were estimated in thirty young individuals during incremental exercise on cycle-ergometer: Heart rate (HR), Oxygen consumption (VO2) and Workload were measured by the two methods (RQA and GE). Repeated measures ANOVA was used to assess main effects of methods and methods-by-groups interaction effects for HR, VO2 and Workload at aerobic (AerT) and anaerobic (AnT) thresholds. Validity of RQA at both thresholds was assessed for HR, VO2 and Workload by Ordinary Least Products (OLP) regression, Typical Percentage Error (TE), Intraclass Correlation Coefficients (ICC) and the Bland Altman plots. No methods-by-groups interaction effects were detected for HR, VO2 and Workload at AerT and AnT. The OLP analysis showed that at both thresholds RQA and GE methods had very strong correlations (r >0.8) in all variables (HR, VO2 and Workload). Slope and intercept values always included the 1 and the 0, respectively. At AerT the TE ranged from 4.02% (5.48 bpm) to 10.47% (8.53 Watts) (HR and Workload, respectively) and in all variables ICC values were excellent (≥0.85). At AnT the TE ranged from 2.53% (3.98 bpm) to 6.64% (7.81 Watts) (HR and Workload, respectively) and in all variables ICC values were excellent (≥0.90). Therefore, RQA of HRV time series is a new valid approach to determine both ventilatory thresholds in individuals with different physical fitness levels, it can be used when gas analysis is not possible or not convenient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.