Accumulated signal noise will cause the integrated values to drift from the true value when measuring orientation angles of wearable sensors. This work proposes a novel method to reduce the effect of this drift to accurately measure human gait using wearable sensors. Firstly, an infinite impulse response (IIR) digital 4th order Butterworth filter was implemented to remove the noise from the raw gyro sensor data. Secondly, the mode value of the static state gyro sensor data was subtracted from the measured data to remove offset values. Thirdly, a robust double derivative and integration method was introduced to remove any remaining drift error from the data. Lastly, sensor attachment errors were minimized by establishing the gravitational acceleration vector from the acceleration data at standing upright and sitting posture. These improvements proposed allowed for removing the drift effect, and showed an average of 2.1°, 33.3°, 15.6° difference for the hip knee and ankle joint flexion/extension angle, when compared to without implementation. Kinematic and spatio-temporal gait parameters were also calculated from the heel-contact and toe-off timing of the foot. The data provided in this work showed potential of using wearable sensors in clinical evaluation of patients with gait-related diseases.
The human joint kinematics is an interesting topic in biomechanics and turns to be useful for the analysis of human movement in several fields. A crucial issue regards the assessment of joint parameters, like axes and centers of rotation, due to the direct influence on human motion patterns. A proper accuracy in the estimation of these parameters is hence required. On the whole, stereophotogrammetry-based predictive methods and, as an alternative, functional ones can be used to this end. This article presents a new functional algorithm for the assessment of knee joint parameters, based on a polycentric hinge model for the knee flexion-extension. The proposed algorithm is discussed, identifying its fields of application and its limits. The techniques for estimating the joint parameters from the metrological point of view are analyzed, so as to lay the groundwork for enhancing and eventually replacing predictive methods, currently used in the laboratories of human movement analysis. This article also presents an assessment of the accuracy associated with the whole process of measurement and joint parameters estimation. To this end, the presented functional method is tested through both computer simulations and a series of experimental laboratory tests in which swing motions were imposed to a polycentric mechanical analogue and a stereophotogrammetric system was used to record them.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.